HD 50R-MB Data Logger with Master RS485 Modbus-RTU Interface
HD 50R-MB Data Logger with Master RS485 Modbus-RTU Interface
HD 50R-MB Data Logger with Master RS485 Modbus-RTU Interface
HD 50R-MB Data Logger with Master RS485 Modbus-RTU Interface

HD50R-MB Data Logger with Master RS485 Modbus-RTU Interface (35 mm DIN RAIL)

Reference: HD50R-MB - Manufacturer: SENSECA (Delta Ohm)

Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting to tipping bucket rain gauge.
It communicates with the PC / PLC via USB or Ethernet local network (proprietary TCP / IP or Modbus TCP / IP protocol).
Number of samples: Min = 259,000, Max = 890,500 (depending on the number of acquired quantities).

Includes Cable CP23 (Cable USB)

 

If the data logger is connected via Ethernet and the local network has an Internet connection, the acquired data is transmitted via e-mail, via FTP and to an HTTP server (Cloud).
Acoustic alarm with internal buzzer and sending of alarm e-mails. External 7 ... 30 Vdc power supply. 35 mm DIN rail installation.
Instrument operating temperature / humidity: -10 ... + 60 ° C / 0 ... 85% RH.


-It includes HD35AP-S downloadable software from Delta OHM web site.
-The external probes have to be ordered separately.
-The CP23 USB cable is included.
-Ethernet cable is not included.

Data logger with Master RS485 Modbus‑RTU interface for acquiring sensors with RS485 Modbus‑RTU output (for example an anemometer of the HD52.3D... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting a tipping bucket rain gauge.

It communicates with the PC/PLC via USB or Ethernet local network (proprietary TCP/IP or Modbus TCP/IP protocol).

Number of samples: Min = 259,000, Max = 890,500 (depending on the number of acquired quantities).

If the data logger is connecetd via Ethernet and the local network has an Internet connection, the acquired data are transmitted via e-mail, via FTP and to an HTTP server (Cloud).

Acoustic alarm with internal buzzer and sending of alarm e-mails.

External 7…30 Vdc power supply.

35 mm DIN rail installation.

Instrument operating temperature / humidity: ‑10…+60 °C / 0…85 % RH.

It includes HDServer1 and HD35AP-S softwares downloadable from Delta OHM website.

-----------------DATA LOGGERS----------------
Data Acquisition
Environment of Use
Indoor
IP Classification
IP54
Communications
RS485 Modbus RTU

16 other products in the same category:

Product added to wishlist
Product added to compare.