INSIDE & OUTSIDE USE HD 35EDW 1NL TC Temperature, Humidity and Leaf Wetness Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NL TC 22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the leaf wetness sensor HP3501 .... View
INSIDE & OUTSIDE USE HD 35EDW S TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S TC 52,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP 3510 ... soil volumetric water content and temperature combined probe. View
INSIDE & OUTSIDE USE HD 35EDW S/2 TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S/2 TC 36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the HP3510 ... soil volumetric water content and temperature combined probes. View
INSIDE & OUTSIDE USE HD 35EDW S/3 TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S/3 TC 26,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector for the HP3510 ... soil volumetric water content and temperature combined probes. View
INSIDE & OUTSIDE USE HD 35EDW DP TC Level and Rainfall Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW DP TC 28,000 samples. Optional custom LCD display (option L).Two inputs: one with M12 connector for the rain gauge and one with cable gland for the level sensor. View
INSIDE & OUTSIDE USE HD 35EDW 1NI2 TCV Temperature, Humidity and Illuminance Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NI2 TCV 30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT03BL illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35EDW 1NB… TV Temperature, Humidity and Carbon Dioxide Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NB… TV 30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. View
INSIDE & OUTSIDE USE HD 35EDW 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Wireless Data... SENSECA (Delta Ohm) HD 35EDW 1NB…I…TCV 26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35EDW 1NB…F TCV Temperature, Humidity, Carbon Dioxide and PAR Light Wireless Data... SENSECA (Delta Ohm) HD 35EDW 1NB…F TCV 26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PAR probe for the measurement of the photons flow in the chlorofyll range. View
INSIDE & OUTSIDE USE HD 35EDW WBGT Wireless Data Logger for the Analysis of the WBGT (Wet Bulb Globe... SENSECA (Delta Ohm) HD 35EDW WBGT 30,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector for the wet bulb temperature probe (TP 3501TC2 or TP3204), the globe-thermometer temperature probe (TP 3575TC2 or TP 3576TC2) and the dry bulb temperature probe (TP 3507TC2) for indoor measurements according to ISO 7243. Installation on VTRAP30 tripod (optional). View
INSIDE & OUTSIDE USE HD 35EDW WBGT-S PROBES FOR WBGT INDEX MEASUREMENT SENSECA (Delta Ohm) HD 35EDW WBGT-S MODELS:- TP 3501TC2- TP 3204- TP 3507TC2- TP 3575TC2- TP 3576TC2- HP 3517ETC2.2- HP 3517ETC2.5- HP 3517ETC2.10- HD 9007A-3- HD 9007T26.2- HD 32.2.7.1- VTRAP30- HD 32.4.17- HD 2013.2.14- HD 3218K View
INSIDE & OUTSIDE USE HD 35EDWP TC Rainfall Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW P TC 36,000 samples. Optional custom LCD display (option L). One input with M12 connector for the rain gauge. View
INSIDE & OUTSIDE USE HD 35EDWP TC-ALM Rainfall Quantity Wireless Data Logger (with alarm contact output) SENSECA (Delta Ohm) HD 35EDW P TC-ALM 36,000 samples. Optional custom LCD display (option L). One input with M12 connector for the rain gauge. View
INSIDE & OUTSIDE USE HD 35EDWH Model with Terminal Head Inputs for Standard Analog Sensors SENSECA (Delta Ohm) HD 35EDWH HD 35EDWH Wireless data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- sensors with voltage free contact output (max one sensor)- potentiometric sensors View
INSIDE & OUTSIDE USE HD 35EDW-MB Wireless Data Logger with RS485 Modbus-RTU Input SENSECA (Delta Ohm) HD 35EDW-MB Allows adding one or more sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series) in the wireless network. View
INSIDE & OUTSIDE USE HD 35EDM TC Wireless Data Logger in IP 67 Waterproof Housing SENSECA (Delta Ohm) HD 35EDM TC Front dimensions 120x122 mm. It can measure temperature, humidity, atmospheric pressure, solar radiation, rainfall quantity, wind speed and direction. It stores the measures in its internal memory (from 28,000 to 58,000 samples depending on the number of detected quantities) and transmits the logged data to the base unit at regular intervals or upon... View
INSIDE & OUTSIDE USE HD 35RE RF signal repeater SENSECA (Delta Ohm) HD 35RE Housing for indoor, Powered by the PC USB port or external power adapter SWD06 (optional). Supplied with: internal lithium-ion rechargeable battery HD35-BAT1, wall mount support HD35.03, operating manual. The kit HD35.11K (pair of flanges, pin for padlock and padlock) for fixed installation and the external power adapter SWD06 have to be ordered separately. View
INSIDE & OUTSIDE USE HD35REW RF signal repeater SENSECA (Delta Ohm) HD35REW Waterproof Housing. Powered by the internal battery. Supplied with: internal lithium-thionyl chloride (Li-SOCl2) not rechargeable battery BAT-2013DB, operating manual. Fixed external antenna. It can be wall mounted by means of the optional HD35.24W flange or fixed on a Ø 40 mm mast by means of the HD2003.77/40 clamping (optional). Optional HD9217TF1... View
INSIDE & OUTSIDE USE HD 35ED-ALM ALARM MODULE SENSECA (Delta Ohm) HD 35ED-ALM Wireless module with two relay outputs for signalling alarm events. Controlled by the base unit, it allows to activate more signalling devices (sirens, blinking lights, etc.) or actuators. View
INSIDE & OUTSIDE USE Serie HD 50... Web Data Loggers SENSECA (Delta Ohm) Serie HD 50... Data logger with integrated Web Server (except HD50R-MB). Depending on the model, it measures temperature, humidity, atmospheric pressure, carbon dioxide and illuminance. View
INSIDE & OUTSIDE USE HD 50 N/1 TC Temperature Data Logger SENSECA (Delta Ohm) HD 50 N/1 TC Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD50N/2-TC Temperature Data Logger Delta-Ohm SENSECA (Delta Ohm) HD50N/2-TC Number of samples: Min = 744,740, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Two inputs with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 50 N/3 TC Temperature Data Logger SENSECA (Delta Ohm) HD 50 N/3 TC Number of samples: Min = 615.220, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Three inputs with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 50 N TV Temperature Data Logger SENSECA (Delta Ohm) HD 50 N TV Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. Fixed vertical probe with NTC10KΩ temperature sensor. View
INSIDE & OUTSIDE USE HD 50 1N TC Temperature and Humidity Data Logger SENSECA (Delta Ohm) HD 50 1N TC Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). View