Industrial Pyranometer SR100-D1 Class B

SR100-D1

Hukseflux

New

Hukseflux introduces “industrial-grade” solar radiation monitoring! The all-digital Class B pyranometer model SR100-D1 is engineered to measure solar radiation with the utmost reliability and measurement accuracy.

Designed for IEC 61724-1 Class B compliant PV system performance monitoring
Integrated surge protection, designed to withstand the extreme conditions encountered on PV power plants, upgradable to 4 kV with optional SPD01 Surge Protection Device
Compliant with IEC 61326-1 “Industrial equipment” – rated for Industrial Electromagnetic Environments
Supported by a worldwide calibration organisation for the lowest total cost of ownership

Add to wishlist

The Sensor measures: Solar Light Radiation W/m2
Communication RS485

Industrial Class B Pyranometer Hukseflux introduces “industrial-grade” solar radiation monitoring!
The all-digital Class B pyranometer model SR100-D1 is engineered to measure solar radiation with the utmost reliability and measurement accuracy.
Designed for IEC 61724-1 Class B compliant PV system performance monitoring
Integrated surge protection, designed to withstand the extreme conditions encountered on PV power plants, upgradable to 4 kV with optional SPD01 Surge Protection Device
Compliant with IEC 61326-1 “Industrial equipment” – rated for Industrial Electromagnetic Environments
Enables system designers to comply with local safety regulations
Designed to minimise integration costs Supported by a worldwide calibration organisation for the lowest total cost of ownership

SR100-D1: Affordable Industrial-Grade Pyranometer

SR100-D1 may look like its predecessor, but in many ways it is a completely new instrument. We built upon the measurement capabilities of the earlier pyranometer model SR10 and tailored the SR100-D1 pyranometer to its most common applications in PV system performance monitoring systems and meteorological stations.

SR100-D1 complies with – Industrial-grade – Immunity, Emission, Electrical, Environmental and Safety requirements for use in these outdoor and industrial environments, greatly improving measurement reliability. Ease of operation is further enhanced through extended functionality and diagnostics.

PV System Performance Monitoring: IEC 61724-1 Class B Compliant

SR100-D1 complies with IEC requirements for “Class B” PV system performance monitoring. If you need a pyranometer that complies with all locations and climatic conditions, consider the SR300-D1 pyranometer.

Immunity to High Voltages and Currents - Surges

SR100-D1 is tested and classified for Industrial Environments according to IEC 61326-1 and IEC 61000-6-2. When designing a measuring system, pyranometer users may reach several levels of immunity.

With the optional Surge Protection Device SPD01 this immunity can be increased to 4 kV. Up to 3 pyranometers can be protected with a single SPD01. A third-party SPD with similar specifications may be used instead.

To attain the required level of immunity for a given installation, some general system components should be included, such as:

  • Lightning protection system
  • Earthing and grounding network
  • External surge protection in addition to the native on-board sensor protection

Electrical Safety in the Workplace

A PV power plant is a potentially hazardous workplace environment. To comply with safety regulations, SR100-D1 features a dedicated earthing terminal for connection to protective earth. When the pyranometer is isolated from the mounting platform, it should still be properly earthed via this terminal. SR100-D1 allows system designers to comply with safety regulations. These are often based on EU and US electrical safety standards such as:

  • EN-50110 Operation of Electrical Installations
  • NFPA 70 National Electrical Code (NEC)

Specification

Details

Measurand Hemispherical solar radiation
ISO 9060:2018 Classification Spectrally flat Class B pyranometer
IEC 61724-1:2021 Compliance Meets Class B PV monitoring system requirements
Dome Protector Included (model DP01)
Instrument Diagnostics Internal humidity
Calibration Certificate Included (content limited according to ISO/IEC 17025, section 7.8.1.3)
Standard Cable Length (not included) 3 m
EMC and Surge Immunity
  • Equipment classification: Industrial Equipment
  • Surge Immunity: Level 2, test level 1 kV
  • With optional SPD01: Level 4, test level 4 kV
Electrical Safety in the Workplace
  • Safety compliance: EU Low Voltage Directive (2014/35/EU) / USA National Electric Code (NFPA70)
  • Earthing terminal: Included on instrument
Digital Communication
  • Communication protocol: Modbus RTU
  • RS-485 isolation voltage: 1.5 kV
  • Hardware interface: 2-wire RS-485

Comparison of Pyranometers

SpecificationSR300-D1SR200-D1SR100-D1
ISO 9060:2018 Classification Spectrally Flat Class A Spectrally Flat Class A Spectrally Flat Class B
IEC 61724-1:2021 Compliance for Solar Irradiance Measurement Meets Class A Requirements Meets Class A Requirements Meets Class B Requirements
Dew and Frost Mitigation Heating Included Not Included Not Included
IEC 61724-1:2021 Compliance for Tilt Measurement Meets Class A Requirements Not Included Not Included
Measurement Accuracy for Daily Sums 2.3% 2.4% 4.6%
Internal Humidity Measurement Yes Yes Yes