INSIDE & OUTSIDE USE HD 35EDWH Model with Terminal Head Inputs for Standard Analog Sensors SENSECA (Delta Ohm) HD 35EDWH HD 35EDWH Wireless data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- sensors with voltage free contact output (max one sensor)- potentiometric sensors View
INSIDE & OUTSIDE USE HD 35EDW-MB Wireless Data Logger with RS485 Modbus-RTU Input SENSECA (Delta Ohm) HD 35EDW-MB Allows adding one or more sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series) in the wireless network. View
INSIDE & OUTSIDE USE HD 35EDM TC Wireless Data Logger in IP 67 Waterproof Housing SENSECA (Delta Ohm) HD 35EDM TC Front dimensions 120x122 mm. It can measure temperature, humidity, atmospheric pressure, solar radiation, rainfall quantity, wind speed and direction. It stores the measures in its internal memory (from 28,000 to 58,000 samples depending on the number of detected quantities) and transmits the logged data to the base unit at regular intervals or upon... View
INSIDE & OUTSIDE USE HD 35RE RF signal repeater SENSECA (Delta Ohm) HD 35RE Housing for indoor, Powered by the PC USB port or external power adapter SWD06 (optional). Supplied with: internal lithium-ion rechargeable battery HD35-BAT1, wall mount support HD35.03, operating manual. The kit HD35.11K (pair of flanges, pin for padlock and padlock) for fixed installation and the external power adapter SWD06 have to be ordered separately. View
INSIDE & OUTSIDE USE HD35REW RF signal repeater SENSECA (Delta Ohm) HD35REW Waterproof Housing. Powered by the internal battery. Supplied with: internal lithium-thionyl chloride (Li-SOCl2) not rechargeable battery BAT-2013DB, operating manual. Fixed external antenna. It can be wall mounted by means of the optional HD35.24W flange or fixed on a Ø 40 mm mast by means of the HD2003.77/40 clamping (optional). Optional HD9217TF1... View
INSIDE & OUTSIDE USE HD 35ED-ALM ALARM MODULE SENSECA (Delta Ohm) HD 35ED-ALM Wireless module with two relay outputs for signalling alarm events. Controlled by the base unit, it allows to activate more signalling devices (sirens, blinking lights, etc.) or actuators. View
INSIDE & OUTSIDE USE Serie HD 50... Web Data Loggers SENSECA (Delta Ohm) Serie HD 50... Data logger with integrated Web Server (except HD50R-MB). Depending on the model, it measures temperature, humidity, atmospheric pressure, carbon dioxide and illuminance. View
INSIDE & OUTSIDE USE HD 50 N/1 TC Temperature Data Logger SENSECA (Delta Ohm) HD 50 N/1 TC Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD50N/2-TC Temperature Data Logger Delta-Ohm SENSECA (Delta Ohm) HD50N/2-TC Number of samples: Min = 744,740, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Two inputs with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 50 N/3 TC Temperature Data Logger SENSECA (Delta Ohm) HD 50 N/3 TC Number of samples: Min = 615.220, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Three inputs with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 50 N TV Temperature Data Logger SENSECA (Delta Ohm) HD 50 N TV Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. Fixed vertical probe with NTC10KΩ temperature sensor. View
INSIDE & OUTSIDE USE HD 50 1N TC Temperature and Humidity Data Logger SENSECA (Delta Ohm) HD 50 1N TC Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 50 17P TC Temperature and Humidity Data Logger SENSECA (Delta Ohm) HD 50 17P TC Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor). View
INSIDE & OUTSIDE USE HD 50 1N TV Temperature and Humidity Data Logger SENSECA (Delta Ohm) HD 50 1N TV Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical probe (with NTC10K temperature sensor). View
INSIDE & OUTSIDE USE HD 50 14bN TC Temperature, Humidity and Atmospheric Pressure Data Logger SENSECA (Delta Ohm) HD 50 14bN TC Number of samples: Min = 356,180, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 50 14b7P TC Temperature, Humidity and Atmospheric Pressure Data Logger SENSECA (Delta Ohm) HD 50 14b7P TC Número de muestras: Mín. = 356,180, Máx. = 906,640 (segundo o número de cantos almacenados). Opcional pantalla LCD personalizada (opção L) ou gráfica (opção G). Una entrada con M12 para a sonda combinada HP3517ETC ... de temperatura e umidade relativa (com sensor de temperatura Pt100). Sensor de presión integrado. View
INSIDE & OUTSIDE USE HD 50 1NB… TV Temperature, Humidity and Carbon Dioxide (CO2) Data Logger SENSECA (Delta Ohm) HD 50 1NB… TV Number of samples: Min = 356,180, Max = 906,640 (depending on the number of stored quantities).Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. View
INSIDE & OUTSIDE USE HD 50 14bNB… TV Temperature, Humidity, Atmospheric Pressure and Carbon Dioxide (CO2)... SENSECA (Delta Ohm) HD 50 14bNB… TV Number of samples: Min = 323,800, Max = 906,640 (depending on the number ofstored quantities). Optional custom (option L) or graphical (option G) LCD display.Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 50 1NI… TCV Temperature, Humidity and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NI… TCV ◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral... View
INSIDE & OUTSIDE USE HD 50 14bNI… TCV Temperature, Humidity, Atmospheric Pressure and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 14bNI… TCV ◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with... View
INSIDE & OUTSIDE USE HD 50 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NB…I…TCV Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT... View
INSIDE & OUTSIDE USE HD 50 14bNB…I… TCV Temperature, Humidity, Atmospheric Pressure, Carbon Dioxide and... SENSECA (Delta Ohm) HD 50 14bNB…I… TCV ◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35... View
INSIDE & OUTSIDE USE HD 50GH Data Logger with LCD Display and four inputs for Thermocouple SENSECA (Delta Ohm) HD 50GH ◆ Data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- potentiometric sensors◆ Number of samples: Min = 615.220, Max = 1,165,680 (depending on the number of stored quantities) depending on the number and type of connected... View
INSIDE & OUTSIDE USE HD50R-MB Data Logger with Master RS485 Modbus-RTU Interface (35 mm DIN RAIL) SENSECA (Delta Ohm) HD50R-MB Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting to tipping bucket rain gauge.It communicates with the PC / PLC... View