- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
FS5021 Transmitter for Air Flow and Volume Flow + Temperature for Air Conducts (output 0-10V or 4-20mA)
- 0-20 m/s, 0...+50°C, 0-200.000 m³/h
- 0-10 V, 4-20 mA
- LCD display, relay
- 5 scales per device
The flow transmitter FS5021 detects the air flow, volume flow and temperature in ventilation ducts. The transmitter converts the measurement result into a linear output signal 0-10 V or 4-20 mA for further processing.
As an option, a potential-free changeover contact and / or a backlit LCD display are available.
In the case of display devices, the DIP switch can be used to switch to volumetric flow. For this, the channel cross-section, channel geometry and immersion depth must be specified in the menu. The volume flow is then calculated from the flow velocity.
The content of the backlit display can be rotated by the menu in 90 ° increments. The actual value, the set switching threshold, the relay status, the MIN / MAX measured values of the selected interval, etc. can be read off.
The airflow sensor works according to the calorimetric measuring principle and has 5 freely selectable scalings, which can simply be switched over as required by innovative DIP-switch technology.
In addition, the switching threshold, hysteresis etc. can be specified.
|
Measuringprinciple |
calorimetric measuring method |
|
Measurementrangeflow |
0-20 m/s |
|
Scales |
0-3 m/s, 0-5 m/s, 0-10 m/s, 0-15 m/s, 0-20 m/s |
|
Measurementrangevolumeflow |
0-200.000 m³/h (calculated) |
|
Measurement range temp. |
0...+50°C |
|
Accuracy |
±0,3 m/s + max. ±4% FS (@ 20°C, 45% r.H., 1013 mbar), ±0,5 K (@ 20°C, > 1 m/s) |
|
Temperature dependency |
±1% FS / 10 K |
|
Long term stability |
±1% FS/year, ±0,2 K/year |
|
Response time (t90) |
> 4 s @ 10 m/s |
|
Running-in time |
< 30 s at initial operation because of tempering |
|
Output attentuation |
5 s |
|
Supply voltage |
24 V AC/DC |
|
Current consumption at 0-10 V |
Ø 100 mA |
|
Current consumption at 4-20 mA |
< 140 mA |
|
Current consumption at relay |
< 120 mA |
|
Analogue output 0-10 V |
3-wire connection, min. load resistance 100 kOhm |
|
Analogue output 4-20 mA |
3-wire connection, max. RLoad(Ohm) = 300 Ohm |
|
Alarm output |
1 x potential-free change-over contact, 48 V, 1 A |
|
Hysteresis |
5% Span, adjustable with display devices |
|
Electrical connection |
screw terminals max. 1,5 mm² |
|
Housing |
Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003 |
|
Cable gland |
PG11 high-strength cable gland with strain relief |
|
Display |
optional 2-line LCD-Display, to display the measured values on location |
|
Material |
Protection tube: stainless steel VA 1.4571 |
|
Protection type |
Housing/electronic: IP65, Sensor: IP30 |
|
Protection class |
III |
|
Working range |
0,3-20 m/s |
|
Working temperature |
-20...+60°C |
|
Storage temperature |
-20...+50°C |
|
Installation |
mounting flange (in scope of delivery) |
|
Approvals |
CE, EAC, RoHS |
.jpg)
- The Sensor measures:
- Air Flow and Volume Flow
- Output Signal:
- 0-10 V or 4-20 mA
- Power Supply:
- 24 Vdc
- Sensor for use in:
- Indoor