- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
R0110E Economic Thermometer (-30 ºC a + 70 ºC.)
Thermometer
Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter. Thermometer is designed for record of temperature.
The device includes Traceable calibration certificate with declared metrological traceability of etalons is based
Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper adapter. Thermometer is designed for record of temperature.
Main thermometer applications:
- Transport of food or pharmaceuticals
- Food and beverage industry (HACCP)
- Pharmaceutical industry
- Blood stations, pharmacies
- Horticulture and cultivation of plants
- HVAC (heating, ventilation, air conditioning, cooling)
- Building and energy management
- Research and development
- Laboratories (GLP)
- Warehouses
- Technological processes
- Museums, archives, galleries
Thermometer advantages:
- Included traceable calibration certificate from the manufacturer
- Fast data transfer to the PC (full memory for approximately 30s)
- Variability of connection to the computer - USB, RS232, Ethernet, GSM modem
- Permanent connection to the PC enabled, data is possible to download even during logging
- Large data memory 32000 values
- Optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- Dual level alarm is enabled for each channel, alarm is indicated by blinking of the LED diode
- Two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared from the PC)
- Robust watertight case
- Low power consumption from battery, battery life up to 7 years
- Indication of remaining battery life, easy replacement of the battery
- It is possible to combine temperature measurement with logging of contact state (e.g. door contact)
- Logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet
- Also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- Each logger is possible to describe with text of maximum 32 characters
- Each channel is possible to describe with text of maximum 16 characters
- Password protection is enabled to prevent unauthorized manipulation with logger
|
Technical parameters |
Value |
|---|---|
|
Measured Value |
Temperature |
|
Construction Type |
Ambient Air |
|
Temperature Measuring Range |
-30 to +70°C |
|
Two-State Input |
No |
|
Lcd Display |
No |
|
Built-In Printer |
No |
|
Operating temperature range |
-30 to +80°C |
|
Accuracy of temperature measurement |
±0.6°C from -30 to +30°C |
|
Resolution of the reading |
0.1°C |
|
Real time clock |
year, leap year, month, day, hour, minute, second |
|
Data logging interval |
adjustable from 10s to 24h |
|
Alarm refresh |
each 10 s |
|
Total memory capacity |
32000 temperature values in noncyclic logging mode |
|
Data logging mode |
noncyclic - data logging stops after filling the memory |
|
Power |
Lithium battery 3,6V, size AA |
|
Typical battery life |
7 years |
|
Battery life in continuous on-line mode with interval 1 minute |
reduced to 70% of the above life |
|
Battery life in continuous on-line mode with interval 10 second |
1 year |
|
IP protection |
IP67 - protected against influence of temporary immersion into water |
|
Dimensions |
93x64x27mm |
|
Weight including battery |
approximately 100g |
|
Warranty |
2 years |

| KIT - GSM/GPRS modem LP040 with accessories for Sxxxx, Rxxxx loggers
code: KIT-GSM-L
![]() |
COM adapter with protection IP65
code: LP012
![]() |
GSM/GPRS MODEM for data loggers of Sxxxx, Rxxxx, Gxxxx families
code: LP040
![]() |
| antenna for GSM modem FASTRACK
code: MP009/1
![]() |
AC/DC adapter 230Vac to 24Vdc/1A, switch-mode
code: A1940
![]() |
Communication cable for GSM modem
code: QMS2901
![]() |
| Transducer USB/RS232 complete
code: MP006
![]() |
Self Adhesive Dual Lock
code: MD036
![]() |
Wall holder for GPRS modem
code: MP036
![]() |
| DIN Rail 35mm holder for GPRS modem
code: MP037
![]() |
One time fee for using M2M server - applied for each data logger with modem
code: SLU302
![]() |
| Start/stop magnet
code: LP004
![]() |
USB adapter
code: LP003
![]() |
USB adapter cable USB A/female - Micro USB/male - OTG
code: OTG
![]() |
| COM adapter with protection IP65
code: LP012
![]() |
LAN adapter with 0.5 meter cable
code: LP005
![]() |
LAN adapter with 5 meter cable
code: LP005-5
![]() |
| Lithium battery 3,6V/AA
code: A4203
![]() |
wall holder for datalogger
code: F9000
![]() |
Self Adhesive Dual Lock
code: MD036
![]() |