F-74A-S (3999960014)
New
• F-74 meter
• Electrode stand
• Protection cover
• Power adaptor with 6 plugs
• Data acquisition software in USB
• 9615S-10D - refillable, glass-body pH electrode with integrated temperature sensor, 1m cable, BNC & phono jack
• 3552-10D - Platinum/Platinum black, glass-body k=1.0 conductivity cell with integrated temperature sensor, 1m cable, BNC & phono jack
• 502-S - pH 4.01, 7.00, 10.01, 3.33M KCl solutions (250ml each)
• 503-S - 84μS/cm, 1413μS/cm, 12.88mS/cm & 111.8mS/cm conductivity standard solutions (250ml each)
This product is no longer in stock
Availability date:
With Display | Color LCD |
Communications | USB, RS232C, analog output |
Memory Capacity | 2000 data |
Power Supply: | AC adaptor 100 240V, 50/60 Hz |
- LAQUA F-74 Dual channel pH/ORP/Ion/EC/Res/TDS/Sal/Temp colour touchscreen bench meter
- 9615S-10D Standard ToupH glass-body, refillable pH electrode with integrated temperature sensor
- 3552-10D Platinum/Platinum black, glass-body, k=1.0 conductivity electrode with integrated temperature sensor
- 502-S USA pH buffers: 4.01, 7.00, 10.01 pH buffers & 3.33 M KCl reference electrolyte (250ml each)
- 503-S Conductivity standards: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (250ml each)
- Data acquisition software in USB flash drive (communication cable is sold separately)
- Electrode stand
- Protection cover
- Power adaptor with 6 plugs (US, UK, EU, Australia / New Zealand, Korea, and China)
- Instruction manual
|
LAQUA F-74 |
---|---|
pH Range |
-2.000 to 20.000 pH |
Resolution |
0.01 / 0.001 pH |
Accuracy |
± 0.001 pH |
Calibration Points |
Up to 5 |
Buffer Options |
USA / NIST / NIST2 / China / Custom |
ORP Range |
± 1999.9 mV |
Resolution |
0.1 mV |
Accuracy |
± 0.2 mV |
Ion Range |
0.000 µg/L to 9999 g/L (mol/L) |
Resolution |
4 significant digits |
Accuracy |
± 0.3% of full scale |
Calibration Points |
Up to 5 |
EC Range |
0.000 µS/cm to 19.99 mS/cm (k=0.1) 0.00 µS/cm to 199.9 mS/cm (k=1) 0.0 µS/cm to 1.999 S/cm (k=10) |
Resolution |
0.05% of full scale |
Accuracy |
± 0.6% of full scale (± 1.5% of full scale > 18.0 mS/cm) |
Reference Temperature |
15 to 30 ºC (adjustable) |
Temperature Coefficient |
0.00 to 10.00 % (adjustable) |
Cell Constants |
0.1 / 1.0 / 10.0 |
Calibration Points |
4 (Auto / Manual) |
Measurement Units |
Auto Ranging / Manual µS/cm, mS/cm, S/m |
TDS Range |
0.01 mg/L to 1000 g/L |
Resolution |
0.01 mg/L |
Accuracy |
± 0.1% of full scale |
TDS Curves |
EN27888 / Linear (0.40 to 1.0) / 442 / NaCl |
|
0.00 kΩ.cm to 199.9 MΩ•cm (k=0.1) 0.000 kΩ.cm to 19.99 MΩ•cm (k=1) 0.0 Ω.cm to 1.999 MΩ•cm (k=10) |
Resolution |
0.05% of full scale |
Accuracy |
± 0.6% of full scale (± 1.5% of full scale > 1.80 MΩ•cm) |
Salinity Range |
0.00 to 80.00 ppt / 0.000 to 8.000 % |
Resolution |
0.01 ppt / 0.001 % |
Accuracy |
± 0.2% of full scale |
Salinity Curves |
NaCl / Seawater |
Temperature Range |
30.0 to 130.0 ⁰C |
Resolution |
0.1 ⁰C |
Accuracy |
± 0.4 ⁰C |
Calibration Option |
Yes |
Navigation Function |
Yes |
Memory |
2000 |
Auto Data-Logging |
Yes |
Data Search |
Yes |
Custom Printing |
Yes |
Real Time Clock |
Yes |
Date / Time Stamp |
Yes |
Sample ID Input |
Yes |
Operator ID Input |
Yes |
Password Setting |
Yes |
Auto Stable / Auto Hold |
Yes |
Offset / Slope Display |
Yes |
Calibration Alarm Limit |
Yes |
Electrode Status |
On screen display |
Diagnostic Messages |
Yes |
Display |
Touchscreen color graphic LCD / dual channel display |
Languages |
English / Japanese / Chinese / |
Inputs |
Dual BNC, dual phono, DC socket |
Outputs |
USB, RS232C, analog output |
Power Requirements |
AC adaptor 100 - 240V, 50/60 Hz |
Electrode Stand |
Stand-alone |
Weight |
700g |
Dimensions |
170 (W) x 174 (D) x 73 (H) mm |