- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
English
EUR €
SI-411 SDI-12 Digital Output Standard Field of View Infrared Radiometer
SDI-12 Digital Output Standard Field of View Infrared Radiometer
"
Apogee infrared radiometers are the most accurate non-contact temperature sensors available anywhere. The SI-411 has an SDI-12 digital output and comes with a 22 degree half angle field of view. The sensor has tinned leads for connecting to a datalogger. Applications include measuring the temperatures of road surfaces, plant canopies, and soil, snow and water surfaces. Measurement of surface temperature is a crucial component of energy transfer. Accurate measurement of the leaf-to-air temperature gradient is essential to the determination of transpiration rate and stomatal conductance in both single leaves and plant canopies.
Input Voltage Requirement: 4.5 to 24 V DC
Current Drain: 1.1 mA (quiescent), 6 mA (transmitting)
Calibration Uncertainty (-20 to 65 C): 0.2 C, when target and detector temperature are within 20 C
Measurement Repeatability: < 0.05 C
Stability (Long-term Drift): less than 2 % change in slope per year when germanium filter is maintained in a clean condition
Response Time: 0.2 s
Field of View: 22° half angle
Spectral Range: 8 to 14 μm; atmospheric window
Operating Environment: -45 to 80 C, 0 to 100 % relative humidity (non-condensing)
Dimensions: 2.3 cm diameter and 6.0 cm length
Mass: 190 g (with 5 m of lead wire)
Cable: 5 m of four conductor, shielded, twisted-pair wire. Additional cable available in multiples of 5 m. Santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions). Pigtail lead wires.
Warranty: 4 years