P37AB147
New
Air Quality + CO & CO2 Probe
At AlphaOmega-Electronics you will find the best range of Data Loggers and at the most competitive prices.
Availability date:
P37AB147 Combinated Probe measures: Temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide) combined probe.
Complete with SICRAM module. Probe Dimensions 275mm x 45mm x 40mm. Connection cable length 2m.
Typical applications of the instrument with the range of sensors mentioned above are:
- Measure IAQ and comfort conditions in schools, offices and indoor.
- Analysis and study of sick building syndrome (Sick Building Syndrome) and
consequences.
- Verification of HVAC system.
- Investigation of IAQ conditions in factories to optimize the microclimate and improve
productivity.
- Audits in Building Automation.
P37B147 CO2 Carbon Dioxide Sensor:
Sensor NDIR Dual Wavelength
Measurement range 0 … 5000ppm
Sensor working range -5 … 50°C
Accuracy ±50ppm+3% of measurement
Resolution 1ppm
Temperature dependence 0.1%f.s./°C
Response time (T90) < 120 sec (air speed = 2m/sec)
P37AB147Carbon Monoxide Sensor:
Sensor Electrochemical cell
Measurement range 0 … 500ppm
Sensor working range -5 … 50°C
Accuracy ±3ppm+3% of measurement
Resolution 1ppm
Response time (T90) < 50 sec
Long-term stability 5% of measurement/year
Service life > 5 years in normal environment conditions
Long-term stability 5% of measurement/5 years
Relative Humidity:
Type of sensor Capacitive
Sensor protection Stainless steel grid filter (on request 20μm sintered filter
P6 in AISI 316 or 10μm sintered filter P7 in PTFE)
Measurement range 0 … 100 % RH
Sensor working range -20 … +60°C
Accuracy ±2% (10÷90% RH) ±2.5% in the remaining range
Resolution 0.1°C
Temperature dependence ±2% on all temperature range
Hysteresis and repeatability 1% RH
Response time (T90) < 20 sec (air speed = 2m/sec) without filter
Long-term stability 1%/year
Temperature:
Type of sensor: NTC 10 KOhm
Measurement range -20 … +60°C
Accuracy ±0.2°C ±0.15% of measurement
Resolution 0.1°C
Response time (T90) < 30 sec (air speed = 2m/sec)
Long-term stability 0.1°C/year
Atmospheric Pressure Patm:
Type of sensor Piezo-resistive
Measurement range 750 … 1100 hPa
Accuracy ±1.5 hPa @ 25°C
Resolution 1 hPa
Long-term stability 2hPa/year
Temperature drift ±3hPa with temperature -20 … +60°C