INSIDE & OUTSIDE USE HD 35EDW 1NR TC Temperature, Humidity and Solar Radiation Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NR TC 24,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the pyranometer LP PYRA 03. View
INSIDE & OUTSIDE USE HD 35EDW 7PR TC Wireless Data Recorder for Solar Radiation and Solar Panel Temperature SENSECA (Delta Ohm) HD 35EDW 7PR TC 36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the TP35878ISS ... Pt100 temperature probe for solar panel, and one for the pyranometer. View
INSIDE & OUTSIDE USE HD 35EDW 1N7PR TC Wireless Data Logger for Humidity, Solar Radiation, Environmental... SENSECA (Delta Ohm) HD 35EDW 1N7PR TC 22,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), one for the pyranometer and one for the TP35878ISS ... Pt100 temperature probe for solar panel. View
INSIDE & OUTSIDE USE HD 35EDW RP TC Solar Radiation and Rainfall Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW RP TC 28,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the pyranometer and the rain gauge. View
SENSORS & PROBES SR15-A1 Analogue "first class" Pyranometer with heater Hukseflux SR15-A1 €1,650.00 Applications: PV system performance monitoring General solar resource monitoring Indoor simulated solar testing Meteorological networks Add to cart
SENSORS & PROBES SR15 Digital "First Class" Pyranometers with various outputs SR15 The new SR15 digital pyranometer series is ideal for general first class high-accuracy measurements in PV system performance monitoring and meteorology. Applications: PV system performance monitoring General solar resource monitoring Indoor simulated solar testing Meteorological networks View
INSIDE & OUTSIDE USE HD 35EDW 1NI2 TCV Temperature, Humidity and Illuminance Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NI2 TCV 30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT03BL illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35EDW 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Wireless Data... SENSECA (Delta Ohm) HD 35EDW 1NB…I…TCV 26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 50 1NI… TCV Temperature, Humidity and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NI… TCV ◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral... View
INSIDE & OUTSIDE USE HD 50 14bNI… TCV Temperature, Humidity, Atmospheric Pressure and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 14bNI… TCV ◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with... View
INSIDE & OUTSIDE USE HD 50 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NB…I…TCV Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT... View
INSIDE & OUTSIDE USE HD 50 14bNB…I… TCV Temperature, Humidity, Atmospheric Pressure, Carbon Dioxide and... SENSECA (Delta Ohm) HD 50 14bNB…I… TCV ◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35... View
INSIDE & OUTSIDE USE LP 35 PHOT Photometric Probe for Measuring Illuminance SENSECA (Delta Ohm) LP 35 PHOT Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction. Measuring range: 0.1 ... 200,000 lux. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LPBL3 Accessories for Photometric and Radiometric Probes SENSECA (Delta Ohm) LPBL3 Adjustable wall support for Ø 30 mm photometric and radiometric probes. View
INSIDE & OUTSIDE USE LP 35 UVA Radiometric Probe for Measuring the Irradiance in the UVA Spectral Range SENSECA (Delta Ohm) LP 35 UVA Radiometric probe for measuring the irradiance in the UVA spectral range (315-400 nm, with peak at 360 nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 10 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 UVB Radiometric Probe for Measuring the Irradiance in the UVB Spectral Range SENSECA (Delta Ohm) LP 35 UVB Radiometric probe for measuring the irradiance in the UVB spectral range (280-315nm, with peak at 305nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 UVC Radiometric Probe for Measuring the Irradiance in the UVC Spectral Range SENSECA (Delta Ohm) LP 35 UVC Radiometric probe for measuring the irradiance in the UVC spectral range (220-280nm, with peak at 260nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 PAR Radiometric Probe to Measure Photon Flow SENSECA (Delta Ohm) LP 35 PAR Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35P -A Combined Probe for measuring the Illuminance and the Irradiance SENSECA (Delta Ohm) LP 35 P-A Combined probe for measuring the illuminance (lux), with standard photopic spectral response, and for measuring the irradiance (W / m2) in the UVA spectral range (315-400 nm, with peak at 360 nm). Both sensors are equipped with diffuser for the correction according to the law.Illuminance measuring range: 0.3 ... 20⋅103 lux. Irradiance measuring range:... View
INSIDE & OUTSIDE USE LP 35 PAR04BL Radiometric Probe to Measure Photon Flow SENSECA (Delta Ohm) LP 35 PAR04BL Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable L = 5 m. Supplied with base with levelling device. View
INSIDE & OUTSIDE USE LP 35 PHOT03BL Photometric Probe for Measuring Illuminance SENSECA (Delta Ohm) LP 35 PHOT03BL Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction, dome in K5. Measuring range: 0.1 ... 200,000 lux. Supplied with base with levelling device. The cable (CPM12 AA5 ... D) has to be ordered separately. View
SENSORS & PROBES LP PYRA 02 PYRANOMETERS SENSECA (Delta Ohm) LP PYRA 02 First Class pyranometer according to ISO 9060. Output in μV / (Wm-2). Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, leveling device, connector and calibration report. On request 5 or 10 m cables with 4-pole M12 connectors. View
INSIDE & OUTSIDE USE 3415FX LightScout Light Sensors Reader Spectrum Technologies 3415FX €399.00 Add to cart
INSIDE & OUTSIDE USE HOBONet Field Monitoring System Onset HOBONet The HOBOnet Field Monitoring System from Onset provides a cost-effective and scalable solution for web-enabled monitoring of field conditions for applications such as crop management, research, and greenhouse operations. BUYING IN BULK, OR JUST WANT SOME USEFUL ADVICE? Call +34 916292106 or complete our More info about this product form Onset Data... View
Spectrum Technologie DLI-100 LightScout Light Meter Spectrum Technologies DLI-100 €99.00 Introducing our new Greenhouse and Turf versionsLightScout DLI 100 Light Meter (Ref.: 3405G)Measure the light “falling” on your plants. The best way to quantify light for growing plants is to measure photosynthetically active radiation light (PAR) between 400 and 700, the range that promotes photosynthesis. The daily light integral (DLI) measures the... Add to cart