INSIDE & OUTSIDE USE HD 50 14b7P TC Temperature, Humidity and Atmospheric Pressure Data Logger SENSECA (Delta Ohm) HD 50 14b7P TC Número de muestras: Mín. = 356,180, Máx. = 906,640 (segundo o número de cantos almacenados). Opcional pantalla LCD personalizada (opção L) ou gráfica (opção G). Una entrada con M12 para a sonda combinada HP3517ETC ... de temperatura e umidade relativa (com sensor de temperatura Pt100). Sensor de presión integrado. View
INSIDE & OUTSIDE USE HD 50 1NB… TV Temperature, Humidity and Carbon Dioxide (CO2) Data Logger SENSECA (Delta Ohm) HD 50 1NB… TV Number of samples: Min = 356,180, Max = 906,640 (depending on the number of stored quantities).Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. View
pH1100 LAQUA Benchtop Meters for Water Quality HORIBA pH1100 (3200647407) Contain: • PH1100 Meter• Electrode stand• Power adapter View
pH1100-S LAQUA Benchtop Meter Kit for Water Quality HORIBA pH1100-S (3999960176) €695.00 Content: • PH1100 meter• Electrode support• Power adapter• Solutions pH 4.01 / 7,00 / 10,01 / 3,33M KCl (250ml)• Combined pH electrode 9615S-10D - refillable, super solid glass body, with temperature sensor and 1 meter cable Add to cart
pH1200 LAQUA Benchtop Meter for Water Quality HORIBA pH1200 (3200647408) Contain: • PH1200 Meter• Electrode stand• Power adapter• Protection cover View
WATER QUALITY pH110 LAQUAact Portable Meter for Water Quality HORIBA pH110 (3200739844) Handheld Meter only (includes electrode attachment, manual & 2 x AAA batteries) View
WATER QUALITY pH110K LAQUAact Portable Meter Kit for Water Quality HORIBA pH110K (3999960167) Handheld Water Quality Meters Kit (pH 110K) (pH 110 / ORP) in carrying case, 9651-10D plastic-body, gel-filled pH electrode; pH 4.01, 7.00, 10.01 (60ml) View
INSIDE & OUTSIDE USE HD 50 14bNB… TV Temperature, Humidity, Atmospheric Pressure and Carbon Dioxide (CO2)... SENSECA (Delta Ohm) HD 50 14bNB… TV Number of samples: Min = 323,800, Max = 906,640 (depending on the number ofstored quantities). Optional custom (option L) or graphical (option G) LCD display.Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 50 1NI… TCV Temperature, Humidity and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NI… TCV ◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral... View
INSIDE & OUTSIDE USE HD 50 14bNI… TCV Temperature, Humidity, Atmospheric Pressure and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 14bNI… TCV ◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with... View
WATER QUALITY pH120 LAQUAact Handheld Meter for Water Quality HORIBA pH120 (3200739845) Handheld Meter only (includes electrode attachment, manual & 2 x AAA batteries) View
INSIDE & OUTSIDE USE HD 50 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NB…I…TCV Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT... View
WATER QUALITY pH120K LAQUAact Portable Meter Kit for Water Quality HORIBA pH120K (3999960168) Handheld Water Quality Meters Kit (pH 120K) (pH 120 / ORP) in carrying case, 9651-10D plastic-body, gel-filled pH electrode; pH 4.01, 7.00, 10.01 (60ml) View
INSIDE & OUTSIDE USE HD 50 14bNB…I… TCV Temperature, Humidity, Atmospheric Pressure, Carbon Dioxide and... SENSECA (Delta Ohm) HD 50 14bNB…I… TCV ◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35... View
INSIDE & OUTSIDE USE HD 50GH Data Logger with LCD Display and four inputs for Thermocouple SENSECA (Delta Ohm) HD 50GH ◆ Data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- potentiometric sensors◆ Number of samples: Min = 615.220, Max = 1,165,680 (depending on the number of stored quantities) depending on the number and type of connected... View
INSIDE & OUTSIDE USE HD50R-MB Data Logger with Master RS485 Modbus-RTU Interface (35 mm DIN RAIL) SENSECA (Delta Ohm) HD50R-MB Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting to tipping bucket rain gauge.It communicates with the PC / PLC... View
INSIDE & OUTSIDE USE HD33M.2 GSM/GPRS Delta-Ohm Data Loggers for Weather Stations SENSECA (Delta Ohm) HD33M.2 ◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected) and transmits the acquired data by email, via FTP and to an HTTP (Cloud) server. USB output. Optional custom LCD display... View
INSIDE & OUTSIDE USE HD33M4b.2 HD33M.GSM Delta-Ohm Data Logger for Weather Stations, equipped with an... SENSECA (Delta Ohm) HD33M4b.2 ◆ HD33M.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa.◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected)... View
INSIDE & OUTSIDE USE HD 32MT.SWD POWER SUPPLY UNITS SENSECA (Delta Ohm) HD 32MT.SWD 100 ... 240 Vac / 24 Vdc power supply unit with switch. Wall-mount or attachment on to ∅ 40 mm mast (to be specified when ordering). Includes the fixing accessories. View
INSIDE & OUTSIDE USE HD 32WSF.S12 POWER SUPPLY UNITS SENSECA (Delta Ohm) HD 32WSF.S12 Unidad de suministro de energía del panel solar con interfaz SDI-12 para leer el voltaje de la fuente de alimentación. Incluye una batería de 12 Vdc / 7.2 Ah y un regulador de carga. La salida de la fuente de alimentación es el voltaje no regulado de la batería interna. Carcasa estanca IP 67 Al realizar el pedido, especifique si el cable de alimentación... View
Water Quality pH130 LAQUAact Handheld Meter for Water Quality HORIBA pH130 (3200739846) Handheld Meter only (includes electrode attachment, manual & 2 x AAA batteries) View
WATER QUALITY pH130K LAQUAact Handheld Meter Kit for Water Quality HORIBA pH130K (3999960169) Handheld Water Quality Meters Kit (pH 130K) (pH 130 / ORP) in carrying case, 9651-10D plastic-body, gel-filled pH electrode; pH 4.01, 7.00, 10.01 (60ml) View
WATER QUALITY DO110 LAQUAact Handheld Meter for Water Quality HORIBA DO110 (3200739848) Handheld Meter only (includes electrode attachment, manual & 2 x AAA batteries) View
WATER QUALITY DO110K LAQUAact Handheld Meter Kit for Water Quality HORIBA DO110K (3999960172) Handheld Water Quality Meters Kit (Dissolved Oxygen DO110) in case, Galvanic DO probe 9551-20D, 2 m cable View
WATER QUALITY DO120 LAQUAact Handheld Meter for Water Quality HORIBA DO120 (3200739849) Handheld Meter only (includes electrode attachment, manual & 2 x AAA batteries) View