- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
English
EUR €
T-CON-ACT-300 ConLab 0-300 Volt AC Transmitter & 4-20mA o/p
0-300 volt self-powered transformer for monitoring sine wave, single-phase AC voltage. Requires Input Cable for use with U12 loggers.
Can be plugged directly into the external input jacks of U12 and ZW Family loggers to expand the range of measurement options and applications.
Environment:
The T-CON-ACT-300 Sensor is for use in Indoor environments
Measurements:
The T-CON-ACT-300 Sensor supports the following measurements: AC Voltage
Note: Not currently CE compliant
- Ranges: 0–300 volts RMS
- Sensor accuracy: < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range)
- Over range: +20% of span
- Over load: +40% of span
- Frequency: 60 Hz AC
- Supply: Self-powered
- Output: 0–20 mA
- Response time to 90%: <240 msec
- Operating Conditions: -20° to 70°C (-4° to 158°F); 5-95% RH, non-condensing
- Housing: Plastic polycarbonate
- Protection Level:
- Box: According to IP-50 DIN 40050
- Terminals: According to IP-10 DIN 40050
- Mounting: Standard 35mm DIN rail
Notes: Because these sensors tie directly into the line, they should be used only by qualified personnel.
Requirements
- For U12 & H8 Loggers: Input Cable (Part # CABLE-4-20mA)
- For HOBO Energy Logger: FlexSmart Analog Module (Part # S-FS-CVIA)
Manual:
T-CON-ACT-300T-CON-ACT-300 ConLab 0-300 Volt AC input Transmitter & 4-20mA o/p
At AlphaOmega-Electronics you will find the best range of Current Transducerand at the most competitive prices.
"
You might also like
Viewed products
FOR ENERGY & ELECTRICITY
AL-2VA Electrocorder Energy Logger for Domestic and Light Commercial Appliances
16 other products in the same category:
SENSORS & PROBES
AO-4836AM Medidor Portátil de Velocidad y Dirección del Viento
INSIDE & OUTSIDE USE