- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
TES-92 Electrosmog meter
Ideal for EMF measurements of mobile/cell phones, base stations and microwave leakage.
Measurement optimized for 900MHz, 1800MHz and 2.7GHz
Non-directional (isotropic) measurement with three-channel (triaxial) measurement probe.
Max Hold and Average functions
Manual store/recall up to 99 sets
Level exceed audible alarm with user selectable threshold
Complete with 9V battery and carrying case
|
Measurement method |
Digital, triaxiol measurement |
|
|
Direclionol characteristic |
Isotropic, trioxiol |
|
|
Measurement range selection |
One continuous range |
|
|
Display resolution |
O. lmV/m, O. l vA/m, 0.0011JW/m2 |
|
|
Setting time |
Typica lly 1s [0 to 90% of meat value) |
|
|
!:>isploy refresh r6te |
Typically 400mS |
|
|
Display type |
LC0 4 digit |
|
|
Audible alarm |
Buzzer |
|
|
Measurement units |
mV/m, V/m, IJA/m, mA/m, fJW/m2, mW/m2 |
|
|
Measurement display value |
Instantaneous measured volue1 maximum value or average value since power-on. |
|
|
Measurement average time (in per·set steps) |
4s to 15 minutes |
|
|
Measureme11t olal'l11 function |
Adiusloble threshold with ON/OFF |
|
|
Measurement calibration Factor CAL |
Adjustable |
|
|
Manual data memory and read storage |
99 sets (only recall by meter) |
|
|
Battery |
9V |
|
|
Battery life |
>15hours |
|
|
Accessory |
.9V battery, Carrying Cose & Manaul |
|
ELECTRICAL:
|
Sensor fyoe |
Electric field (E). |
|
Frequency ranQe |
50MHz to 3.5GHz |
|
Directional characteristic |
Isotropic, 3-dimensional. |
|
Measurement ronge (CW signal > 50MHzl |
38mV/m to ll V/m. 3.8µW/m2 to 320mW/m 2 |
|
Absolute error (@l V/m and 50MHz) |
±1.0dB |
|
Frequency response (taking into account typ. CAL factor |
±1 .0dB (50MHz to 1.9GHz) ±2.4dB (1 .9GHz to 3.5GHz) |
|
Isotropy deviatkm |
Typ.± 1.OdB for f >50MHz |
|
overload limit |
4.2W/m2 (40V/m) |
|
Temperature reSponse (0 to 50°C) |
±l .5dB |
|
Note : Unless otherwise stated, all specifications hold under the following assumptions : Sinusoidal signals;device in for·field of a source; probe head pointing toward source; ambient temperature +23°C:t3°C; relative air humidify 25% to 75%. |
|