INSIDE & OUTSIDE USE HD 50 1NI… TCV Temperature, Humidity and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NI… TCV ◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral... View
INSIDE & OUTSIDE USE HD 50 14bNI… TCV Temperature, Humidity, Atmospheric Pressure and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 14bNI… TCV ◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with... View
INSIDE & OUTSIDE USE HD 50 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Data Logger SENSECA (Delta Ohm) HD 50 1NB…I…TCV Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT... View
INSIDE & OUTSIDE USE HD 50 14bNB…I… TCV Temperature, Humidity, Atmospheric Pressure, Carbon Dioxide and... SENSECA (Delta Ohm) HD 50 14bNB…I… TCV ◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35... View
INSIDE & OUTSIDE USE HD 50GH Data Logger with LCD Display and four inputs for Thermocouple SENSECA (Delta Ohm) HD 50GH ◆ Data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- potentiometric sensors◆ Number of samples: Min = 615.220, Max = 1,165,680 (depending on the number of stored quantities) depending on the number and type of connected... View
INSIDE & OUTSIDE USE HD50R-MB Data Logger with Master RS485 Modbus-RTU Interface (35 mm DIN RAIL) SENSECA (Delta Ohm) HD50R-MB Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting to tipping bucket rain gauge.It communicates with the PC / PLC... View
INSIDE & OUTSIDE USE HD33M.2 GSM/GPRS Delta-Ohm Data Loggers for Weather Stations SENSECA (Delta Ohm) HD33M.2 ◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected) and transmits the acquired data by email, via FTP and to an HTTP (Cloud) server. USB output. Optional custom LCD display... View
INSIDE & OUTSIDE USE HD33M4b.2 HD33M.GSM Delta-Ohm Data Logger for Weather Stations, equipped with an... SENSECA (Delta Ohm) HD33M4b.2 ◆ HD33M.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa.◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected)... View
INSIDE & OUTSIDE USE HD 32MT.SWD POWER SUPPLY UNITS SENSECA (Delta Ohm) HD 32MT.SWD 100 ... 240 Vac / 24 Vdc power supply unit with switch. Wall-mount or attachment on to ∅ 40 mm mast (to be specified when ordering). Includes the fixing accessories. View
INSIDE & OUTSIDE USE HD 32WSF.S12 POWER SUPPLY UNITS SENSECA (Delta Ohm) HD 32WSF.S12 Unidad de suministro de energía del panel solar con interfaz SDI-12 para leer el voltaje de la fuente de alimentación. Incluye una batería de 12 Vdc / 7.2 Ah y un regulador de carga. La salida de la fuente de alimentación es el voltaje no regulado de la batería interna. Carcasa estanca IP 67 Al realizar el pedido, especifique si el cable de alimentación... View
INSIDE & OUTSIDE USE HD 33T.GSM Wireless Data Logger in IP 67 Waterproof Housing SENSECA (Delta Ohm) HD 33T.GSM Wireless data logger in IP 67 waterproof housing, specifically designed for monitoring perishable goods during transport. Front dimensions 120x122 mm. It can measure temperature, humidity and detect the state of an external voltage-free contact. It stores the measures in its internal memory (from 136,000 to 440,000 samples depending on the number of... View
INSIDE & OUTSIDE USE HD 33T4b.GSM Wireless Data Logger in IP 67 Waterproof Housing SENSECA (Delta Ohm) HD 33T4b.GSM HD33T.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa. View
INSIDE & OUTSIDE USE LP 35 PHOT Photometric Probe for Measuring Illuminance SENSECA (Delta Ohm) LP 35 PHOT Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction. Measuring range: 0.1 ... 200,000 lux. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LPBL3 Accessories for Photometric and Radiometric Probes SENSECA (Delta Ohm) LPBL3 Adjustable wall support for Ø 30 mm photometric and radiometric probes. View
INSIDE & OUTSIDE USE LP 35 UVA Radiometric Probe for Measuring the Irradiance in the UVA Spectral Range SENSECA (Delta Ohm) LP 35 UVA Radiometric probe for measuring the irradiance in the UVA spectral range (315-400 nm, with peak at 360 nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 10 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 UVB Radiometric Probe for Measuring the Irradiance in the UVB Spectral Range SENSECA (Delta Ohm) LP 35 UVB Radiometric probe for measuring the irradiance in the UVB spectral range (280-315nm, with peak at 305nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 UVC Radiometric Probe for Measuring the Irradiance in the UVC Spectral Range SENSECA (Delta Ohm) LP 35 UVC Radiometric probe for measuring the irradiance in the UVC spectral range (220-280nm, with peak at 260nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35 PAR Radiometric Probe to Measure Photon Flow SENSECA (Delta Ohm) LP 35 PAR Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable length 5 m M12 connector. View
INSIDE & OUTSIDE USE LP 35P -A Combined Probe for measuring the Illuminance and the Irradiance SENSECA (Delta Ohm) LP 35 P-A Combined probe for measuring the illuminance (lux), with standard photopic spectral response, and for measuring the irradiance (W / m2) in the UVA spectral range (315-400 nm, with peak at 360 nm). Both sensors are equipped with diffuser for the correction according to the law.Illuminance measuring range: 0.3 ... 20⋅103 lux. Irradiance measuring range:... View
INSIDE & OUTSIDE USE LP 35 PAR04BL Radiometric Probe to Measure Photon Flow SENSECA (Delta Ohm) LP 35 PAR04BL Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable L = 5 m. Supplied with base with levelling device. View
INSIDE & OUTSIDE USE LP 35 PHOT03BL Photometric Probe for Measuring Illuminance SENSECA (Delta Ohm) LP 35 PHOT03BL Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction, dome in K5. Measuring range: 0.1 ... 200,000 lux. Supplied with base with levelling device. The cable (CPM12 AA5 ... D) has to be ordered separately. View
SENSORS & PROBES LP PYRA 02 PYRANOMETERS SENSECA (Delta Ohm) LP PYRA 02 First Class pyranometer according to ISO 9060. Output in μV / (Wm-2). Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, leveling device, connector and calibration report. On request 5 or 10 m cables with 4-pole M12 connectors. View
Colorimeters CLRM-300 Precision Colorimeter Ф8mm Measuring Aperture MRC CLRM-300 CLRM-300 Precision Colorimeter View
COLORIMETERS/GLOSS METERS NHG268 Precise Gloss Meter with 20/60/85 degrees 3nh NHG268 €1,050.00 NHG268 Precise Gloss Meter with 20/60/85 degrees. ◆ 20°, 60°, 85° Gloss◆ Three Measuring Modes◆ Screen-touch◆ GQC6 Software Add to cart