INSIDE & OUTSIDE USE HD35EDW… Data Loggers in Waterproof Housing SENSECA (Delta Ohm) HD35EDW Wireless data logger in IP 67 (IP65 for the models measuring CO2) waterproof housing. Front dimensions 120x80 mm. It stores the measures in its internal memory and transmits the logged data to the base unit automatically at regular intervals or upon request.Optional LCD display. Transmitting range in open field: 300 m (E, J) / 180 m (U) with internal... View
INSIDE & OUTSIDE USE HD 35EDW 7P/1 TC Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 7P/1 TC 68,000 samples. Optional custom LCD display (option L). One input with M12 connector for Pt100 / Pt1000 temperature probes. View
INSIDE & OUTSIDE USE HD 35EDW N/1 TC Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW N/1 TC 68,000 samples. Optional custom LCD display (option L). One input with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 35EDW N/3 TC Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW N/3 TC 42,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector for NTC10KΩ temperature probes. View
INSIDE & OUTSIDE USE HD 35EDW N TV Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW N TV 68,000 samples. Optional custom LCD display (option L). Fixed vertical probe with NTC10KΩ temperature sensor. View
SENSORS & PROBES FS5020 Laminar Duct Air Flow and Volumetric Flow + Temperature Transmitter (0-10 V or... Fuehler Systeme FS5020 0-5 m/s, 0...+50°C 0-10 V, 4-20 mA LCD display, relay 5 scales per device View
SENSORS & PROBES FS5021 Transmitter for Air Flow and Volume Flow + Temperature for Air Conducts (output... Fuehler Systeme FS5021 €270.00 - 0-20 m/s, 0...+50°C, 0-200.000 m³/h - 0-10 V, 4-20 mA - LCD display, relay - 5 scales per device Add to cart
INSIDE & OUTSIDE USE HD 35EDW 7P/3 TC Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 7P/3 TC Temperature wireless data logger. 42,000 samples Optional custom LCD display (option L). Three inputs with M12 connector for Pt100 / Pt1000 temperature probes. View
INSIDE & OUTSIDE USE HD 35EDW N TV61 Temperature Wireless Data Logger for Freezing Tunnels SENSECA (Delta Ohm) HD 35EDW N TV61 68,000 samples. Optional custom LCD display (option L). Fixed vertical probe with NTC10KΩ temperature sensor. View
INSIDE & OUTSIDE USE HD 35EDW K/4 TC Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW K/4 TC 36,000 to 68,000 samples depending on the number of inputs used. Optional custom LCD display (option L). Four inputs with connector for K-J-T-N-E hermocouple temperature probes. View
INSIDE & OUTSIDE USE HD 35EDW 1 TV Relative humidity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1 TV 68,000 samples. Optional custom LCD display (option L). Fixed vertical probe. View
INSIDE & OUTSIDE USE HD 35EDW 1 TVI Relative humidity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1 TVI 68,000 samples. Optional custom LCD display (option L). Fixed vertical probe. View
INSIDE & OUTSIDE USE HD 35EDW 1N TC Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35EDW 1N TC 24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 35EDW 17P TC Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35EDW 17P TC 24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor, extended temperature range). View
INSIDE & OUTSIDE USE HD 35EDW 1N TV Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35EDW 1N TV 24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 35EDW 1N TVI Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35EDW 1N TVI 24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with temperature sensor integrated in the R.H. module). View
INSIDE & OUTSIDE USE HD 35EDW 1N/2 TC Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35EDW 1N/2 TC 22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC ... temperature and relative humidity combined probe with NTC10KΩ temperature sensor, and one for the temperature only probes with NTC10KΩ sensor (two combined T / RH probes can not be connected). View
INSIDE & OUTSIDE USE HD 35EDW 14bN TC Temperature, Humidity and Atmospheric Pressure Wireless data logger SENSECA (Delta Ohm) HD 35EDW 14bN TC 22,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35EDW 14b7P TC Temperature, Humidity and Atmospheric Pressure Wireless data logger SENSECA (Delta Ohm) HD 35EDW 14b7P TC 22,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor, extended temperature range). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35EDW R TC Solar Sadiation Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW R TC 42,000 samples. Optional custom LCD display (option L). One input with M12 connector for the pyranometer. View
INSIDE & OUTSIDE USE HD 35EDW 1NR TC Temperature, Humidity and Solar Radiation Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NR TC 24,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the pyranometer LP PYRA 03. View
INSIDE & OUTSIDE USE HD 35EDW 7PR TC Wireless Data Recorder for Solar Radiation and Solar Panel Temperature SENSECA (Delta Ohm) HD 35EDW 7PR TC 36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the TP35878ISS ... Pt100 temperature probe for solar panel, and one for the pyranometer. View
INSIDE & OUTSIDE USE HD 35EDW 1N7PR TC Wireless Data Logger for Humidity, Solar Radiation, Environmental... SENSECA (Delta Ohm) HD 35EDW 1N7PR TC 22,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), one for the pyranometer and one for the TP35878ISS ... Pt100 temperature probe for solar panel. View
INSIDE & OUTSIDE USE HD 35EDW RP TC Solar Radiation and Rainfall Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW RP TC 28,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the pyranometer and the rain gauge. View
INSIDE & OUTSIDE USE HD 35EDW NP TC Rainfall Quantity and Temperature ireless Data Logger SENSECA (Delta Ohm) HD 35EDW NP TC 28,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the rain gauge and the TP350NTC ... temperature probe (with NTC10KΩ sensor). View
Laboratory, Pharmacy, Vaccine, Transport & Storage Real-time monitoring, single use Temperature, Location FRIGGA-B9Z FRIGGA FRIGGA-B9Z €65.00 - Full visibility of the cold chain- Manage and improve your cold chain- Traceable and analyzable data- Improved satisfaction through online concept help Old A80 and A90 Add to cart
INSIDE & OUTSIDE USE HD 35EDW 1NP TC Rainfall Quantity, Temperature and Humidity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NP TC 22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the rain gauge and the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 35EDW 1NL TC Temperature, Humidity and Leaf Wetness Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NL TC 22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the leaf wetness sensor HP3501 .... View
INSIDE & OUTSIDE USE HD 35EDW S TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S TC 52,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP 3510 ... soil volumetric water content and temperature combined probe. View
INSIDE & OUTSIDE USE HD 35EDW S/2 TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S/2 TC 36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the HP3510 ... soil volumetric water content and temperature combined probes. View
INSIDE & OUTSIDE USE HD 35EDW S/3 TC Soil Volumetric Water Content (VWC) and Temperature Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW S/3 TC 26,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector for the HP3510 ... soil volumetric water content and temperature combined probes. View
INSIDE & OUTSIDE USE HD 35EDW DP TC Level and Rainfall Quantity Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW DP TC 28,000 samples. Optional custom LCD display (option L).Two inputs: one with M12 connector for the rain gauge and one with cable gland for the level sensor. View
INSIDE & OUTSIDE USE HD 35EDW 1NI2 TCV Temperature, Humidity and Illuminance Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NI2 TCV 30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT03BL illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35EDW 1NB… TV Temperature, Humidity and Carbon Dioxide Wireless Data Logger SENSECA (Delta Ohm) HD 35EDW 1NB… TV 30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. View
INSIDE & OUTSIDE USE HD 35EDW 1NB…I…TCV Temperature, Humidity, Carbon Dioxide and Illuminance Wireless Data... SENSECA (Delta Ohm) HD 35EDW 1NB…I…TCV 26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35EDW 1NB…F TCV Temperature, Humidity, Carbon Dioxide and PAR Light Wireless Data... SENSECA (Delta Ohm) HD 35EDW 1NB…F TCV 26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PAR probe for the measurement of the photons flow in the chlorofyll range. View