- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
RK500-04 Dissolved Oxygen Sensor (Output signal: 4-20mA and RS485)
RK500-04 Dissolved Oxygen (DO) Sensor is based on the principle of quenching excited fluorescence by specific substances in physics.
◆ Simple operation and high reliability.
◆ No external module, a whole design.
◆ Long service life, maintenance-free.
◆ Dissolved oxygen and temperature measurement at the same time
◆ Output signal: 4-20mA and RS485 at the same time.
◆ No requirement for liquid velocity.
◆ Not affected by ions.
When the excited light is irradiated on the fluorescent substance on the surface of the fluorescent film head, the fluorescent substance is excited and emits fluorescence.
The fluorescence extinction time is affected by the concentration of oxygen molecules on the surface of the fluorescent film head. So the oxygen molecule concentration can be calculated by detecting the fluorescence extinction time.
By using green light and unique phase technology, the membrane lifespan attenuation is reduced, and it can be used for more than 2 years without the need for calibration.
DO sensor can be widely used in chemical fertilizer, metallurgy, environmental protection water treatment, engineering, pharmaceutical, biochemical, food, aquaculture and water such as continuous monitoring ofdisso lved oxygen in the solution.
.jpg)
- Environmental protection
- Water quality monitoring
- Aquaculture
- Clean in place (CIP)
- Sewage treatment
- Industrial wastewater treatment
.jpg)
Dissolved Oxygen (DO) Sensor RK500-04A Economy
DO Range: 0-20 mg/L
Temperature Range: 0-60 °C (RS485 only)
Power Supply: 12-24 V
Output: RS485 and 4-20 mA
5 m Cable (for freshwater, agriculture, aquaculture, riverbeds, etc.)
Dissolved Oxygen (DO) Sensor RK500-04B Performance
DO Range: 0-20 mg/L, 0-50 mg/L
Temperature Range: 0-60 °C (RS485 only)
Power Supply: 12-24 V
Output: RS485 and 4-20 mA
5 m Cable (for industrial control, general wastewater, environmental monitoring, etc.)
Dissolved Oxygen (DO) Sensor RK500-04C Anti-corrosion
DO range: 0-20 mg/L, 0-50 mg/L
Temperature range: 0-60 °C (RS485 only)
Power supply: 12-24 V
Output: RS485 and 4-20 mA
5 m cable (for seawater, strong corrosion resistance, mariculture, highly corrosive wastewater, complex environments, etc.)
- The Sensor measures:
- Dissolved Oxigen
- Output Signal:
- 4-20 mA or RS485
- Cable Length:
- 5 meters
- Power Supply:
- 7 - 28 Vdc
- Sensor IP Rating
- IP68
- Sensor for use in:
- Outdoor & Underwater