AO-RK500-23
New
Soil EC Sensor: EC range 0~1000us/cm, 0~2000us/cm,0~5000us/cm,0~10000us/cm
Supply 7-30V, Output: RS485/4-20mA
5m cable (for fresh water)
Quantity | Price (tax excl.) |
You Save % |
---|---|---|
1+ | 349,00 € | 0% |
2+ | 314,10 € | 10% |
3+ | 296,65 € | 15% |
5+ | 286,18 € | 18% |
10+ | 279,20 € | 20% |
This product is no longer in stock
Availability date:
Precision | ±1% |
The Sensor measures: | Conductivity / Salinity |
Output Signal: | 4-20 mA or RS485 |
Cable Length: | 5 meters |
Power Supply: | 7 - 30 Vdc |
Sensor IP Rating | IP68 |
- Electrical Conductivity in SOIL
- On-line & real-time measurement
- Titanium alloy electrode & teflon lining
- High accuracy
- Electromagnetic isolation
- Strong resistance to corrosion
- Polarization resistance
- Integral design without external transmitter
- RS485 and 4-20mA output
Soil salinity sensor integrates graphite electrode and precision platinum resistance, to measure the soil salt through temperature compensation algorithm. After submerged into the soil, it can directly test salt content in the soil.
FEATURES
* On-line & real-time measurement
* With temperature compensation
* High accuracy
* Simple operation and high reliability
* Fast response
* Strong resistance to corrosion
APPLICATIONS
* Environmental protection
* Agriculture & planting
* Forestry
* Soil quality measurement
* Sewage treatment
* Oil and gas pipeline corrosion monitoring
1. In Soil
Section installation
In the area of need to measure dig a soil profile, determine the position of the sensor and depth in the section, the section on level to dig deep for 10-20 cm round hole, insert the sensor level until the bottom of the hole, then filled out of the clay compaction, to ensure that the sensor electrode surface closely contact with soil.
Sensors buried, the soil pit backfill compaction sequence according to the original soil layer.
Ground stiletto installation
In the measurement area, down from the ground to play a hole to the desired depth, sensor inserted to the bottom of the hole, closely contact with the soil, will then stratified backfill compaction.
Measure the soil solution
Take a 1 mm sieve separation of 20.00g dried soil, put in 250 ml bottle drying triangle, add distilled water, 100 ml (water:soil = 5:1), oscillation for 5 minutes, the filtered in dry triangle in the bottle.Take the filtered solution 30 ml, placed in small 50 ml beaker, the sensor electrode in the leaching liquid to be tested.
Item |
Technical Specification |
|
EC | Salinity | |
Measuring medium |
Soil or similar to soil |
|
Principle |
Frequency conversion method |
|
Range |
0~1000us/cm, 0~2000us/cm,0~5000us/cm,0~10000us/cm,0~200ms/cm,(any range of 0-300ms/cm can be customized, 1ms/cm = 1000us/cm) |
0~100000ppm(mg/L)
1ppm(mg/L)=1000ppb(ug/L)=1000000ppt(ng/L)
|
Supply | 7-30VDC(power consumption<0.2W) | |
Accuracy |
±1% |
|
Response time |
1s |
|
Output Signal |
4-20mA & RS485 at the same time |
|
Electrode |
Titanium alloy
|
/ |
Temperature compensation |
/ |
Automatic compensation |
Drift | ≤0.3%FS/24h | |
Operating Temperature | -20℃-+80℃ | |
Probe material | 316L | |
Probe material | Φ13*175mm | |
Ingress Protection | IP68 | |
Storage | 10-60℃@20%-90%RH | |
Cable length | Default:5m |
Example: AO-RK500-23EAA5000 EC sensor, Supply:7-30V, Output:4-20mA, Cable length:5m.
960,00 €