INSIDE & OUTSIDE USE HD 35 Series Wireless Data Logger (with/without LCD display) SENSECA (Delta Ohm) HD 35 It stores the measures in its internal memory and transmits the logged data to the base unit automatically at regular intervals or upon request. Optional Custom or Graphic LCD display. Transmitting range in open field: 300 m (E, J) / 180 m (U). Acoustic alarm with internal buzzer. Powered by the internal battery. Supplied with: internal 3.6V not... View
INSIDE & OUTSIDE USE HD 35AP3G (USB + 3G module) SENSECA (Delta Ohm) HD 35AP3G Like HD35APG but with 3G functionality in addition.Base unit for the interface between PC and system data loggers. USB connectionIntegrated GSM module to send emails or alarm SMS and recorded data via email, via FTP and to an HTTP server (Cloud). It allows communication with the PC through the GPRS TCP / IP protocol. SMS messages can be sent to the base... View
INSIDE & OUTSIDE USE HD 35APD (USB) "Dongle" base unit for interfacing among PC and data loggers of the system. SENSECA (Delta Ohm) HD 35APD USB connection. Powered only by the USB port PC (the unit has not internal battery). Internalantenna It includes HD35AP-S downloadable software from Delta OHM web site. View
INSIDE & OUTSIDE USE HD 35APGMT (USB + GSM Module) Base unit in IP 65 housing for outdoor SENSECA (Delta Ohm) HD 35APGMT USB connection. Integrated GSM module for sending alarm e-mail or SMS and recorded data via e-mail, via FTP and to an HTTP server (Cloud). Allows the communication with the PC through the GPRS TCP / IP protocol. SMS messages can be sent to the base unit, to control the GSM functions of the unit. 18 ... 27 Vdc power supply (from a 12 V solar panel, not... View
INSIDE & OUTSIDE USE HD35AP3GMT (USB + 3G Module) SENSECA (Delta Ohm) HD35AP3GMT Like HD35APGMT but with 3G functionality in addition. View
INSIDE & OUTSIDE USE HD 35ED 1N TC Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35ED 1N TC 24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 35ED 17P TC Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35ED 17P TC 24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor). View
INSIDE & OUTSIDE USE HD 35ED 1N TV Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35ED 1N TV 24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with NTC10KΩ temperature sensor). View
INSIDE & OUTSIDE USE HD 35ED 1N TVI Temperature and Humidity Wireless data logger SENSECA (Delta Ohm) HD 35ED 1N TVI 24,000 samples. Optional custom or graphic LCD display (option L or G). Fixed vertical probe (with temperature sensor integrated in the R.H. module). View
INSIDE & OUTSIDE USE HD 35ED 14bN TC Temperature, Humidity and Atmospheric Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 14bN TC 22,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35ED 14bN TV Temperature, Humidity and Atmospheric Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 14bN TV 22,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35ED 14bN TVI Temperature, Humidity and Atmospheric Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 14bN TVI 22,000 samples. Optional graphic LCD display (option G). Fixed vertical temperature and relative humidity combined probe (with temperature sensor integrated in the R.H. module). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35ED 1N4r… TV Temperature, Humidity and Differential Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 1N4r… TV 22,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Pressure input for Ø 5 mm tubes. View
INSIDE & OUTSIDE USE HD 35ED 1N4r5 TV Temperature, Humidity and Differential Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 1N4r5 TV For clean rooms. 22,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Pressure input for tubes with 5 mm internal diameter. Metal pressure inputs with tube clamp ring to minimize pressure losses. View
INSIDE & OUTSIDE USE HD 35ED 4r… Differential Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 4r… 68,000 samples. Optional custom LCD display (option L). Pressure input for Ø 5 mm tubes. View
INSIDE & OUTSIDE USE HD 35ED 4r5 Differential Pressure Wireless data logger SENSECA (Delta Ohm) HD 35ED 4r5 68,000 samples. For clean rooms. Optional custom LCD display (option L). Pressure input for tubes with 5 mm internal diameter. Metal pressure inputs with tube clamp ring to minimize pressure losses. View
INSIDE & OUTSIDE USE HD 35ED 1NI… TCV Temperature, Humidity and Illuminance Wireless data logger SENSECA (Delta Ohm) HD 35ED 1NI… TCV 44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35ED 1NI TV Temperature, Humidity and Illuminance Wireless data logger SENSECA (Delta Ohm) HD 35ED 1NI TV 44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35ED 14bNI… TCV Temperature, Humidity, Atmospheric Pressure and Illuminance Wireless... SENSECA (Delta Ohm) HD 35ED 14bNI… TCV 36,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ). Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35ED 14bNI TV Temperature, Humidity, Atmospheric Pressure and Illuminance Wireless... SENSECA (Delta Ohm) HD 35ED 14bNI TV 36,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).Photodiode with spectral response similar to the standard photopic curveV (λ) .Integrated pressure sensor. View
INSIDE & OUTSIDE USE HD 35ED 1NIU TCV Temperature, Humidity, Illuminance and UVA Irradiance Wireless data... SENSECA (Delta Ohm) HD 35ED 1NIU TCV 32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 P-A illuminance and UVA irradiance combined probe. Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35ED 1NIU TV Temperature, Humidity, Illuminance and UVA Irradiance Wireless data logger SENSECA (Delta Ohm) HD 35ED 1NIU TV 32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Photodiode with spectral response similar to the standard photopic curve V (λ). View
INSIDE & OUTSIDE USE HD 35ED 1NUB TCV Temperature, Humidity and UVB Irradiance Wireless data logger SENSECA (Delta Ohm) HD 35ED 1NUB TCV 44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 UVB irradiance probe. View
INSIDE & OUTSIDE USE HD 35ED 1NUC TCV Temperature, Humidity and UVC Irradiance Wireless data logger SENSECA (Delta Ohm) HD 35ED 1NUC TCV 44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 UVC irradiance probe. View
INSIDE & OUTSIDE USE HD 35ED 14bNIU TCV Temperature, Humidity, Atmospheric pressure, Illuminance and UVA... SENSECA (Delta Ohm) HD 35ED 14bNIU TCV 32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 P-A illuminance and UVA irradiance combined probe. Photodiode with spectral response similar to the standard photopic curve V (λ). Integrated pressure sensor. View