- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
AO-RRF(P)/A Humidity Transducer without display with Pendular Probe (0...100% r.H)
Humidity Transducer with Pendular Probe (0...100% r.H) without display
The AO-RRF(P)/A humidity transducer with pendular sensor measures the relative humidity 0...100% r.H. of the ambient air by a capacitive sensor and transforms it to a standardised output signal 0-10 V or 4-20 mA. The humidity sensor is protected against contamination by a sinter filter. In addition, the humidity measuring instrument has an integrated heating function for sensor protection in the high humidity range of 95...99% r.H. If the relative humidity exceeds the factory-preset threshold value for more than 10 minutes, this heating function is activated. Then the sensor will be temporally heated, thus dried respectively protected against condensation. During the heating and subsequent temperature compensation phase, the output signal is kept stable on the last measurement value before the protective function was activated. The humidity transducer can be adjusted locally for fine calibration by an offset controller.
| Measurement range r.H. | 0...100% r.H. |
|---|---|
| Accuracy | ±3% r.H. (30%...70% r.H., else ±5% r.H. at 20°C) |
| Temperature dependency | < 0,02% r.H. / °C (voltage output), < 0,04% r.H. / °C (current output) |
| Long term stability | ±1%/year |
| Sensor | capacitive humidity sensor |
| Sensor protection | screwable stainless steel sinter filter, condensation protection by heating function in the range of 95...99% r.H. |
| Flow rate | < 2 m/s |
| Supply voltage at 0-10 V | 24 V AC/DC (±5%) |
| Supply voltage at 4-20 mA | 15...36 V DC (Ubmin = 15 V + RLast*0,02A) |
| Current consumption at 0-10 V | typ. 10 mA |
| Current consumption at 4-20 mA | max. 20 mA |
| Analogue output 0-10 V | 3-wire connection, load current <0,1 mA |
| Analogue output 4-20 mA | 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub - 15 V) / 0,02 A |
| Electrical connection | screw terminals max. 1,5 mm² |
| Cable | 2 m shielded PVC cable |
| Housing | polyamide with snap closing screws, colour white like RAL 9010 |
| Cable gland | PG11 high-strength cable gland with strain relief |
| Display | optional LCD-Display, to display the actual humidity |
| Material | Pendulum: brass nickel-plated |
| Dimensions | Protection tube: Ø 16 x 60 mm |
| Protection type | IP65 |
| Protection class | III |
| Working range r.H. | 0...98% r.H. in contaminant-free, non-condensing air |
| Working temperature | Probe: -20...+80°C, Electronic: -30...+70°C |
| Storage temperature | -20...+50°C |
| Installation | screw fastening |
| Approvals | CE-conformity, EAC, RoHS |