- Home
- Who We Are
- Products
-
Brands
-
Products by Measure
- Vibration Analyzers
- Peristaltic Pumps
- Airflow
- CO Carbon Monoxide
- Geiger counters
- Destiladores
- Spectrophotometry
- Sterilization
- Fluorescence
- GEOTECHNICS
- Soil Moisture
- Leaf area index
- Rain Gauge
- Meteorology
- Water Level
- O2 Oxygen
- pH
- Differential Pressure
- Radiation
- Salinity/Conductivity
- Telemetry
- Air Speed
- Relative Humidity
- Veterinary
- FUEL CELL HARDWARE
- Network Analyzers
- Calibrators
- WATER FLOW
- Color / Colorimeter
- Particle Counters
- Wind Direction
- Spectrometry
- Evapotranspiration
- Photosynthesis
- Cracks in Buildings
- Pipes Inspection
- Quantum Light
- Movement & GPS
- Diesel Level
- Oxígeno Disuelto DO
- Atmospheric Pressure
- Radon
- Sap/Sap Flow
- Temperature
- AIR QUALITY
- Ammonia
- Chlorophyll
- Conductivity in Soil
- Dendrometers
- Electrochemistry
- Spectroradiometry
- Pharmacy & Medicine
- GAS (ANALYZERS)
- Leaf Wetness
- Idc (DC Current)
- KW & KW/H
- PAR Light
- Nitrate
- Occupation and Time
- Particle Meters
- Soil Water Potential
- Pulses
- Flavor/Taste/Acidity
- Sodium
- Turbidity
- VOC
FCA3000 Three Phase Rogowski Coil converter
Applications
- True RMS current measurement
- PLC interface
- Power monitoring and control systems
- Individual machine loading
- SCADA systems
- Very high current measurement
"
- Three Rogowski coils input channels
- Three true RMS DC outputs
- One DC output for channels sum
- 0÷20 mA, 4÷20 mA or 0÷10 VDC output
- Response time selectable by jumpers
- Suitable for three-phase systems
- 3000 A standard full scale value
- Customizable full scale up to hundreds kA
- Compact 9 DIN modules size
Power supply
Rated voltage: 80÷260 VAC (45-65 Hz)
Consumption: 3 VA max
Measuring inputs
No.: 3
Type: for Rogowski coil with signal equalization
Sensitivity: 100 mV/kA standard value
Full scale: 3000 A @ 100 mV/kA standard value
from 300 A to 300 kA on request
Analog outputs
No.: 4
Type: 0÷20mA standard value
4÷20mA or 0÷10 VDC on request
Response time: 150 ms default value - selectable by jumpers from 50 to 150 ms approx.
Typical accuracy: ± 1% reading ± 0.3% full scale
Environmental conditions
Operating temperature: from -10°C to +50°C
Storage temperature: from -25°C to +60°C
Relative humidity: 75% max. without condensation
Case features
Material: plastic enclosure - noryl UL94-V0
Protection degree: IP51 (front panel); IP20 (terminals)
Terminals: conductors 2.5 mm2
Size / weight: 158x94x58 mm / 250 gr approx.
Standards compliance
Safety: 73/23/EEC and 93/68/EEC directives, EN61010.1 safety standard
EMC: 89/336/EEC directive and following modifications 93/31/EEC and 93/68/EEC, EN50081-2, EN50082-2, EN61326/A1