U20-001-01-TI de Titanio para Nivel Agua & Temp. para Agua Salada (0 a 9 m)

U20-001-01-TI

Onset

New

769,00 €

Imposto Excluido

The HOBO U20-001-01-TI Water Level Titanium se recomienda para registrar niveles de agua y temperatura en aplicaciones y zonas de agua salada y en áreas de mareas.
Ofrece una alta precisión a un precio asequible. Además, es de fácil uso y no requiere mantenimiento al no ser necesario que se cambien las bolsas desecantes y al estar diseñado sin incómodos tubos de ventilación.

Protección contra relámpagos - no long signal wires, and electronics are shielded in a titanium housing for use in saltwater (see the Water Level logger sensor location drawing)

HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure temperature, and water density.
Multiple-rate sampling allows faster sampling at critical times such as when pumping starts or stops.
Also available in narrow depth range (U20-001-04-Ti)
Ideal for use in wells, streams, lakes, wetlands and tidal areas
No-vent-tube design for easy reliable deployment
Available in stainless and titanium versions
Durable ceramic pressure sensor
Incluido Certificado de Calibración de 3-puntost traceable-NIST.

Entorno:
El U20-001-01-Ti Data Logger es para uso en entornos de Intemperie y Bajo Agua

Medidas:
El U20-001-01-Ti Data Logger soporta las siguientes medidas: Temperatura, Presión Barométrica, Nivel de Agua

Medidas de Presión y Nivel de Agua con U20-001-01 y U20-001-01-Ti
Rango Operativo 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
Rango Calibrado desde Fábrica 69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
Presión Momentánea 310 kPa (45 psia) or 18 m (60 ft) depth
Precisión de Nivel de Agua* Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water
Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water
Precisión Básica** ±0.3% FS, 0.62 kPa (0.09 psi) maximum error
Resolución <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
Pressure Response Time (90%)*** <1 second; measurement accuracy also depends on temperature response time
Temperature Measurements (All Models)
Rango Operativo -20° to 50°C (-4° to 122°F)
Precisión ±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A
Resolución 0.10°C at 25°C (0.18°F at 77°F), see Plot A
Tiempo de respuesta (90%) 5 minutes in water (typical)
Estabilidad (Deriva) 0.1°C (0.18°F) per year
Registrador
Reloj Tiempo-Real ± 1 minute per month 0° to 50°C (32° to 122°F)
Batería 2/3 AA, 3.6 Volt lithium, factory-replaceable
Vida de la Batería (Uso Típico) 5 years with 1 minute or greater logging interval
Memoria (No-volátil) 64K bytes memory (approx. 21,700 pressure and temperature samples)
Peso Stainless steel models: approximately 210 g (7.4 oz)
Titanium models: approximately 140 g (4.8 oz)
Dimensiones 2.46 cm (0.97 inches) diameter, 15 cm (5.9 inches) length; mounting hole 6.3 mm (0.25 inches) diameter
Wetted Materials Titanium, Viton® o-rings, acetyl cap, ceramic sensor
Logging Interval Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to the HOBOware software manual.
Launch Modes Immediate start and delayed start
Offload Modes Offload while logging; stop and offload
Indicación de Batería Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.

* Water Level Accuracy: With accurate reference water level measurement, known water density, accurate Barometric Compensation Assistant data, and a stable temperature environment.

** Raw Pressure Accuracy: Absolute pressure sensor accuracy includes all sensor drift, temperature, and hysteresis-induced errors.

*** Changes in Temperature: Allow 10 minutes in water to achieve full temperature compensation of the pressure sensor. Maximum error due to rapid thermal changes is approximately 0.5%.