CTV-A Transductor Sensor de corriente AC 0-20Amp con cable de salida a HOBO
Válido para fase y neutro.
Rangos disponibles (Amperios AC): 0-20, 0-50, 0-100, 0-200, 0-600 A
Ratio y precisión lineal: ±4.5% del fondo de escala
Tiempo de respuesta: aproximadamente 250 milisegundos desde 10% al 90% de la amplitud
Corriente de entrada: corriente AC, onda senoidal, fase sencilla 50 Hz o 60 Hz, factor de potencia de carga 0.5 a 1.0 avanzado o retardado
Tasa de Voltaje: Hasta 600 Vac testado con impulso de onda completa de 10 KV durante 60 segundos
Entorno de construcción y operación: Cubierta de plástico para interior tipo UL506; con brazo movible
Cable de 1.8 metros con clavija para conexión al canal externo del registrador HOBO.
A split-core AC current sensor responsive over the range of 2 to 20 amps AC for use with U12, UX120 and ZW data loggers with external input channels. With an input current of AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag.
The molded-plastic housing is rated for indoor use per UL508.
- UL listed
- Sensor power induced from line voltage
- Self-gripping split-core design for fast installation
Environment:
The CTV-A Sensor is for use in Indoor environments
Measurements:
The CTV-A Sensor supports the following measurements: AC Current
|
Número de Ref. |
Rango |
Ventana |
Longitud externa | Anchura externo |
Altura |
| CTV-A | 0-20 A ac | 2.8 cm | 7.4 cm | 6.6 cm | 2.54 cm |
| CTV-B | 0-50 A ac | 2.8 cm | 7.4 cm | 6.6 cm | 2.54 cm |
| CTV-C | 0-100 A ac | 2.8 cm | 7.4 cm | 6.6 cm | 2.54 cm |
| CTV-D | 0-200 A ac | 3.8 cm | 9.9 cm | 11.9 cm | 2.8 cm |
| CTV-E | 0-600 A ac | 7.4 cm | 13.5 cm | 15.0 cm | 2.8 cm |
Accuracy with H8: ±5.0% of full scale<br>
Accuracy with U12: ±4.5% of full scale<br>
Accuracy with UX120-006M: ±2.1% of full scale
Response time (from 10% to 90% of amplitude): see table
Input current: AC current, sine wave, single phase 50 Hz or 60 Hz, load power factor 0.5 to 1.0 lead or lag
Voltage rating: 600 VAC
Construction and operating environment: Molded plastic housing for indoor use per UL508; pivoting leg (leg on CTV-D and CTV-E units is fully removable); UL listed.
Cable Length: 1.8m cable (6 foot)
Dimensiones: ver tabla
Manual:
CTV-A Transductor Sensor de corriente AC
- El Sensor mide:
- Corriente AC
- Señal de Salida:
- 0 a 2,5 VDC
- Longitud del Cable:
- 1,8 m
- Alimentación:
- No requiere
- Sensor para uso en:
- Interior
- Accesorios Sensores:
- Abrazaderas