Ningún producto
Estos precios se entienden sin IVA
Nuevo
Dos modelos a escoger:
PR2 / 4 Tiene Elementos Sensores a 10, 20, 30 y 40cm
PR2 / 6 Tiene Elementos Sensores en 10, 20, 30, 40, 60 y 100cm
La sonda PR2 está disponible en versiones Analógica y SDI-12.
Disponible el:
El Sensor mide: | Humedad del Suelo |
Sensor para uso en: | Intemperie |
Accesorios Sensores: | Varios |
No other soil moisture probe system enables you to monitor your soil water profiles with such ease and flexibility. Install an access tube into the soil, insert the PR2 Profile Probe and press the HH2 [Read] button to display an instantaneous reading, or connect the PR2 to a data logger (DL6 or DL2e) and leave the system to record soil moisture changes over time.
The PR2 soil moisture probe is built around newly patented sensing technology which provides unprecedented performance in all soil types, with minimal influence from either salinity or temperature. The PR2/4 model measures soil moisture at 4 depths down to 40cm or the PR2/6 measures at 6 depths down to 100cm.
The PR2 Profile Probe access tube requires an installation hole 27mm in diameter, allowing easy installation and minimal soil disturbance. Access tubes are manufactured to strict tolerances and are exceptionally strong and durable in the soil. Correct installation is essential and we recommend the use of our specially designed augering equipment.
The PR2 Profile Probe is available in two sizes to measure to a depth of 40cm or 100cm.
The PR2/4 has sensing elements at 10/20/30/40cm
The PR2/6 has sensing elements at 10/20/30/40/60 and 100cm
Data Logging
Delta-T offers two types of data logger with dedicated PR2 Profile Probe
input channels and connectors:
The DL6 Data Logger can log one PR2/6 or one PR2/4 Profile Probe.
The GP2 Data Logger can log up to two PR2/6s or three PR2/4s.
Complete Auger Kit
Access tube installation is vital.
Especificaciones breves |
|
Range |
0 to 0.4 m3.m-3 [1] |
Accuracy |
± 0.04 m3.m-3 |
Output |
PR2/6: 6 x 0 to 1.0V [2] |
Power |
5.5 to 15V [3] |
Sensing depths |
PR2/6: 10, 20, 30, 40, 60, 100 cm |
Sampling Volume |
Vertically: ~95% sensitivity within ± 50mm of upper rings. |
Size |
PR2/4: 750 x 25.4mm dia. |
Sealing |
IP68 |
Access tubes |
|
Size |
ATL1: 1154mm x 28mm dia |
[1] Measures full range up to 1.0 m3.m-3 with reduced accuracy
[2] Corresponding to 0 to 0.6 m3.m-3
[3] 5.5V DC with 2m cable, 7.5V with 100m
|
Ver cómo instalar el PR2. El siguiente video explica cómo se puede usar la sonda tanto para lecturas portátiles como para monitorización a largo plazo, y muestra cómo se pueden tomar con facilidad mediciones precisas de la humedad del perfil del suelo (hasta 1 metro).