UX90-001 Registrador de Datos para Estados, Pulsos, Eventos, y Tiempo
El registrador de datos HOBO State / Pulse / Event / Runtime registra cambios de estado, pulsos electrónicos y cierres de contacto mecánicos o eléctricos de dispositivos de detección externos.
- HOBO UX90-001: modelo de memoria de 128 KB capaz de realizar 84.650 mediciones
- HOBO UX90-001M: versión de memoria ampliada de 512 KB capaz de realizar más de 346,795 mediciones.
Registrador Datos de Estado HOBO UX90-001 (128KB de memoria) y UX90-001M (512KB de memoria)
- Medidas Soportadas:
Eventos, Kilovatios Hora (kWh), Motor On/Off, Pulsos de Entrada, Runtime, State Open/Closed, Water Flow
- Rango: Interno: Conmutador Magnético Reed
Contacto Entrada Externa: Electronic solid state switch closure or logic driven voltage output - Recambio para modelos antiguos: H06-001-02, U9-001
-
The HOBO State/Pulse/Event/Runtime data logger records state changes,electronic pulses and mechanical or electrical contact closures from external sensing devices. This logger is ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow. The HOBO UX90-001 State Logger is available in a standard 128 KB memory model (UX90-001) capable of 84,650 measurements and an expanded 512KB memory version (UX90-001M) capable of over 346,795 measurements.
Características:- One logger with 4 recording modes
- Internal reed switch can be used to determine when a door or window is open or closed
- Compatible with a wide range of external sensors
- Ships with 2.5 mm input cable (CABLE-2.5-STEREO)
Entorno:The UX90-001 Data Logger is for use in Indoor environmentsMeasurements:The UX90-001 Data Logger supports the following measurements : Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed, Water Flow
Sensor Interno
Maximum State, Event, Runtime Frequency: 1 Hz
Preferred Switch State: No magnet present (normally open)
Entrada Externa
External Contact Input: Electronic solid state switch closure or logic driven voltage output
Rango: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)
Maximum Pulse Frequency: 50 Hz
Maximum State, Event, Runtime Frequency: 1 Hz
Pulse, Event Lockout Time: 0 to 1 second in 100 ms steps
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal Weak Pull-Up: 100 KΩ
Input Impedance: Solid state switch closure: 100 KΩ pull up
Logger
Resolución: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy: ±1 minute per month at 25°C (77°F) (see Plot A)
Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memoria:
UX90-001: 128 KB (84,650 measurements, maximum)
UX90-001M: 512 KB (346,795 measurements, maximum)
Download Type: USB 2.0 interface
Download Time: 10 seconds for 128 KB; 30 seconds for 512 KB
Logger Operating Range:
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
- Entorno de Uso
- Interior
- Tipo de Registrador
- Portable
- Parámetros Medidos
- Pulsos
- Aplicación
- Energía y Consumo
- Capacidad Memoria
- 128K
CONTADORES DE CAUDAL
Contador de chorro múltiple de esfera seca para agua fría | MTKD-N / MTKD-M (-CC)
CONTADORES DE CAUDAL
ETKD/ETWD Contador de Caudal de Agua de chorro único y esfera seca para agua fría y...
CONTADORES DE CAUDAL
MTW Contadores de Caudal Agua Caliente
También podría interesarle