Aqualyzer-9040/7040
New
Silica, Phosphate, Hydrazine, Ammonia, Copper and Ethylene Glycol Analyzers Waltron
Availability date:
Our Colorimetric Analyzers (Aqualyzer® Series 9040/7040) are based on the new patented Loop Flow Analysis (LFA) cycle.
Series 9040 is a fixed model and the 7040 model is portable.
Common application points in a boiler system for silica measurement include: make-up water, condensate, boiler feedwater, saturated steam/main steam and cooling water. Application points for phosphate include: boiler water and cooling water.
LFA technology involves isolating,manipulating and testing a known volume of sample in a closed loop system. A powerful programmable microprocessor allows for customized program cycles,ensuring accuracy and reliability with every application.
FEATURES | BENEFITS | |
Highest accuracy | Low reagent and standard consumption | |
Widest range analysis | Minimal maintenance required | |
Single sream or dual stream | Automatic operation | |
Short cycle times | ||
Automatic dilution when above normal concentration range | ||
Automatic calibration | ||
Adjustable cycle and calibration frequency | ||
Ultra-low reagent consumption and smallest size instruments | ||
No reagent pumps or compressed air requirements | ||
Grab sample capability | ||
Last 400 results stored internally |
Sensor Classification | Colormetric with glass flowcell and LED source | |
Application | Demineralized,boiler,potable,surface and waste water | |
Power Requirements | 12V | |
Power Supply | 110-120V or 220-240V 50/60 Hz, 100 VA | |
Humidity | Up to 90% not condensable | |
Ambient Temperature Range | 10-45º C analyzer (50-113º F) | |
Range |
Silica: 0-500 ppb, 0-5000 ppb, 0-200 ppm* |
|
Accuracy | Silica: +/– 1 ppb or +/– 2% of reading, whichever is greater Phosphate, Hydrazine, Ammonia, Copper, Ethylene Glycol: +/- 2% of full scale |
|
Unit Dimensions | Height = 15.5' (39.4 cm), Width = 6.25” (15.88 cm), Depth = 22” (55.9 cm) | |
Atmospheric Pressure Range | No Limits | |
Effect of Electromagnetic Fields | EMC tested according to CE compliance | |
Tolerance to Electrostatic Discharges | EMC tested according to CE compliance | |
Response Time (approximate) | Silica: 10 min, Phosphate: 6 min, Hydrazine: 12 min, Ammonia: 12 min, Copper: 9 min, Ethylene Glycol: 10 min | |
Alarms | Concentration,cal error,out of service/sample | |
Reproducibility | Silica: +/– 1 ppb or +/– 2% of reading, whichever is greater Phosphate, Hydrazine, Ammonia, Copper, Ethylene Glycol: +/– 2% of reading |
|
Degree of Protection | IP65 (NEMA 4x | |
Required Maintenance | Replenish reagents,once a year replace tubing | |
Reagent Consumption(approximate) | Silica, Phosphate, Ammonia, Copper: 1 liter each per month Hydrazine, Ethylene Glycol: 4 liters each per month |
|
Reactor Volume | 10ml | |
Materials in Contact with Sample | Glass, Silicone, Plexiglass, Stainless Steel AISI 316 | |
CE Certification | Meets low voltage and low electromagnetic compatibility directives | |
Sample Conditioning Requirements | Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging. Internal disposable filters supplied (60 micron). | |
Sample Delivery Operating Conditions | ||
Temperature Range | 5-55°C (41-131° F) | |
Turbidity | Not applicable; sample blank correction | |
Color | Not applicable; sample blank correction | |
PH | 3-12 | |
Signal Outputs | ||
4-20 mA, 0-5V | 4-20mA (galvanic isolator module available as option) or 0-5V | |
Printer Options | Optional, serial output RS 232 or RS 485 | |
Serial I/O for Signals | Serial data output RS 232 or RS 485 available as option | |
Operational Calibration | ||
Frequency/Intervals | Recommended.: 7 days | |
Single/Multi Point | Multi-Point:zero and mid range | |
Matrix Corrections | Yes, sample blank correction | |
Manual/Automatic | Both |