UX120-017 4 Channel Pulse/Event, State & Run-Time Data Logger

Onset

New

Data Logger HOBO

240,00 €

tax excl.

Add to wishlist

Number of Channels 4 Digital
ADC Bits 32 bits
With Display No
IP Classification Indoor IP50
Communications USB
Battery Life 1 year
Maximum Pulse Rate 120 Hz
Memory Capacity 520,192 or 4,124,672 measurements

This 4-channel energy data logger UX120 combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals -- from energy auditors to building commissioners -- to easily track building energy consumption, equipment runtimes, and water and gas flow rates.

Simultaneously measures and records pulse signals, events, state changes, and runtimes
Capable of 500,000 measurements (over 4 million with expanded memory version), enabling longer deployments with fewer site visits
Maximum pulse rate – 120 Hz
Pulse input range – 0 to 24VDC
Streamlines deployment via a range of start/stop options, logger status LEDs, and high-speed USB 2.0 data offload
Works with Onset's Energy & Power Meter T-VER-E50B2 to measure Power Factor (PF), Reactive Power (VAR), Watt Hours (Wh) and more.

HOBO 4-Channel Pulse Data Logger Memory Options:
Model UX120-017 with >500,000 Measurement Memory.
Model UX120-017M with >4 Million Measurement Memory.

Supported Measurements (sensors sold separately):
AC Current
AC Voltage
Amp Hour (Ah)
Amps (A)
Event,
Kilowatt Hours (kWh)
Kilowatts (kW),
Motor On/Off
Power Factor (PF), Pulse Input
Run-time
Volt-Amp Reactive (VAR)
Volt-Amp Reactive Hour (VARh)
Volt-Amps (VA)
Volts (V)
Watt Hours (Wh)
Watts (W)

Simultaneously measures and records pulse signals, events, state changes, and runtimes
Stores up to over 500,000 measurements, enabling longer deployments with fewer site visits
Maximum pulse rate – 120 Hz
Pulse input range – 0 to 24VDC

Inputs:
External Contact Input: Electronic solid state switch closure or logic driven digital signals to 24 V
Maximum Pulse Frequency: 120 Hz
Maximum State, Event, Runtime Frequency: 1 Hz
Bits: 4–32 bits depending on pulse rate and logging interval
Maximum Pulses Per Interval: 7,863,960 (using maximum logging rate)
Driven Logic Signal: Input Low: ≤ 0.4 V; Input High: 3 to 24 V
Absolute Maximum Rating: Maximum Voltage: 25 V DC
Minimum Voltage: -0.3 V DC
Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ
Internal Weak Pull-Up: 100 KΩ
Input Impedance: Solid state switch closure: 100 KΩ pull up; Driven signal: 4.5 KΩ
Minimum Pulse Width: Contact closure duration: 500 uS; Driven logic signal: 100 uS
Lockout Time: 0 to 1 second in 100 ms steps
Edge Detection: Falling edge, Schmitt Trigger buffer
Preferred Switch State: Normally open or Logic '1' state
Logging:
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Time Accuracy: ± 1 minute per month at 25°C (77°F) (see Plot A on next page)
Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts
Memory:
Memory UX120-017: 520,192 measurements (assumes 8-bit)
UX120-017M: 4,124,672 measurements (assumes 8-bit)
Download Type USB 2.0 interface
Download Time 30 seconds for UX120-017, 1.5 minutes for UX120-017M
Physical:
Operating Range Logging: -40° to 70°C (-40° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Weight 149 g (5.26 oz)
Size 11.4 x 6.3 x 3.3 cm (4.5 x 2.5 x 1.3 inches)
Environmental Rating IP50

30 other products in the same category: