UX100-014M
New
Availability date:
Number of Channels | 1 Thermocouple |
ADC Bits | 12 bit |
Precision | ±0.21°C |
Resolution | 0.024°C |
With Display | Yes |
IP Classification | Indoor IP50 |
Communications | USB |
Battery Life | 1 year |
Memory Capacity | 84,650 measurements |
The HOBO UX100-014M Single Channel Thermocouple data logger records temperature in indoor environments with thermocouple sensors (sold separately). Designed for a broad range of monitoring applications – from industrial process monitoring to concrete maturity testing – the logger provides exceptional flexibility by accepting J, K, T, E, R, S, B or N type thermocouple probes.
Onset also offers a four-channel thermocouple data logger, the HOBO UX120-014M.
This data logger operates in an indoor environment.
The UX100-014M data logger supports the following measurement: Temperature
Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing); logger accuracy from 0° to 50°C (32° to 122°F)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
Resolution: 22-bit
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: ±1 minute per month at 25°C (77°F), see Plot B
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 512 KB (208,076 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 1 minute, 30 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50
- The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)
Type | Range | Accuracy | Resolution |
J | -210° to 760°C (-346° to 1,400°F) | ±0.6°C (±1.08°F) ± thermocouple probe accuracy | 0.03°C (0.06°F) |
K | -260° to 1,370°C (-436° to 2,498°F) | ±0.7°C (±1.26°F) ± thermocouple probe accuracy | 0.04°C (0.07°F) |
T | -260° to 400°C (-436° to 752°F) | ±0.6°C (±1.08°F) ± thermocouple probe accuracy | 0.02°C (0.03°F) |
E | -260° to 950°C (-436° to 1,742°F) | ±0.6°C (±1.08°F) ± thermocouple probe accuracy | 0.03°C at (0.05°F) |
R | -50° to 1,550°C (-58° to 2,822°F) | ±2.2°C (±3.96°F) ± thermocouple probe accuracy | 0.08°C (0.15°F) |
S | -50° to 1,720°C (-58° to 3,128°F) | ±2.2°C (±3.96°F) ± thermocouple probe accuracy | 0.08°C (0.15°F) |
B | 550° to 1,820°C (1,022° to 3,308°F) | ±2.5°C (±4.5°F) ± thermocouple probe accuracy | 0.1°C (0.18F) |
N | -260° to 1,300°C (-436° to 2,372°F) | ±1.0°C (±1.8°F) ± thermocouple probe accuracy | 0.06°C (0.11°F) |
Internal 10K Thermistor (Temperature)
Range: Logging: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
Resolution: 0.024°C at 25°C (0.04°F at 77°F); see Plot A
Drift: <0.1°C (0.18°F) per year
165,00 €
550,00 €
430,00 €
1 275,00 €
245,00 €
330,00 €
59,00 €
155,00 €
190,00 €
215,00 €
89,00 €
149,00 €
52,00 €
215,00 €
276,00 €
43,00 €
58,00 €
195,00 €
105,00 €
14,00 €
85,00 €
105,00 €
130,00 €
48,00 €
25,00 €
259,00 €