AO-HT-128
New
The principle of electromagnetic induction is used to measure the thickness of a non-magnetic coating and a galvanizing layer (such as paint) on a magnetic conductive metal substrate (such as iron). The principle of the effect of eddy currents is used to measure the thickness of a non-conductive coating (such as paint) on a non-magnetic conductive metal substrate (such as aluminum).
This product is no longer in stock
Availability date:
Performance
Projetado especificamente para atender aos requisitos da indústria automotiva
Calibração de ponto zero fácil
3 tipos de resolução ajustável para diferentes aplicações
Coleta de dados em alta velocidade
Design delicado para fácil operação manual
Método de teste apenas
Desligamento automático
Fácil conversão entre métrico e inchOperating
measurement mode:
Single continuous unit: um, mm
Range: 0 ~ 1300um
Resolution: 1um (0 ~ 999um); 0.01mm (≧ 1000um)
Accuracy: ± 3% + 2um (0 ~ 1300um) Off
automatic: 3 min (no key operation)
Funcionament condition:
Power supply: two 1.5V AAA batteries
Operating temperature: 0 ~ 45 ℃ (no condensation and no strong magnetic field)
Operating humidity: 0 ~ 90% RH non-condensing
Storage temperature : -10 ~ 50 ℃ (14 ~ 122 ℉)
Storage humidity: 0 ~ 90% RH non-condensing
Requirements for the substrate:
Substrate thickness: > 0.5mm
Radius of curvature of the convex surface: > 1.5 mm Radius of
concave surface curvature: > 25mm
Measurement area diameter: > 6mm
Others:
Display: LCD display with backlight
Weight: 80g (battery not included)
Screen size: 112mm × 51mm × 28mm
Accessories:
One piece of standard aluminum substrate
One piece of iron substrate
standard Standard foil: one piece of 50um, 100um, 250um, 500um, 1000um respectively.
Two 1.5V AAA batteries
USB data line
Performance measurement mode:
Single continuous unit: um, mm
Range: 0 ~ 1300um
Resolution: 1um (0 ~ 999um); 0.01mm (≧ 1000um)
Accuracy: ± 3% + 2um (0 ~ 1300um) Off
automatic: 3 min (no key operation)
Funcionament condition:
Power supply: two 1.5V AAA batteries
Operating temperature: 0 ~ 45 ℃ (no condensation and no strong magnetic field)
Operating humidity: 0 ~ 90% RH non-condensing
Storage temperature : -10 ~ 50 ℃ (14 ~ 122 ℉)
Storage humidity: 0 ~ 90% RH non-condensing
Requirements for the substrate:
Substrate thickness: > 0.5mm
Radius of curvature of the convex surface: > 1.5 mm Radius of
concave surface curvature: > 25mm
Measurement area diameter: > 6mm
Others:
Display: LCD display with backlight
Weight: 80g (battery not included)
Screen size: 112mm × 51mm × 28mm
Accessories:
One piece of standard aluminum substrate
One piece of iron substrate
standard Standard foil: one piece of 50um, 100um, 250um, 500um, 1000um respectively.
Two 1.5V AAA batteries
USB data line