Dymas24 ALBEN
New
Multichannel Seismic Recorder
Availability date:
The Dymas 24 Alben is a multichannel acquisition system suitable for long term monitoring for stable configuration inside dams and structures.
The system setup ranges from 6, 12 up to 48 channels in multiples of 6 (with or without communication modules) positioned in a single metallic cabinet provided for wall or floor fixing.
Dymas 24 Seismic Recorder is used for both Microseismic & Vibrational studies.
Connection to remote system is provided by HSDPA/UMTS, GPRS/GSM, OPTICAL FIBER MODEM, WiFi and VHF. Equipped with optical modems for fast data transfer .The management softwareDYMASOFT, integrated with VIBROSOFT data processing software allows to build up efficient dynamic monitoring networks.
The Dymas 24 seismic recorder is compatible with both the 3D-1D Veloget Geophone or Force Balance Accelerometers from Solgeo. The Dymas is ideal for use in dynamic monitoring of civil & industrial structures such as dams,bridges,chimneys & rock noise.
SYSTEM | |
Input Channels | Up to 48 channels |
Configuration | Standalone or multi-station network |
Timing | Internal RTC updated via GPS or remote control – simultaneous sampling |
Triggering Mode | Threshold level and/or STA/LTA, selectable for each channel |
Recording Mode | Internal/external trigger, continuous, selectable post- trigger length Recording of weighted pick values (min-Max), according to DIN 4150 part II, selectable 1 to 100s |
Data Storage | 2 Gb internal memory card for 6 channel group (till to 32GB optional) |
Diagnostics | Battery voltage, temperature, sensors test |
Power Consumption | 2W for 6 channel group (active) |
Communication | Ethernet TCP/IP via cable/wireless, modem GPS, USB2.0, UMTSHSDPA |
24 BIT MODULE | |
Converter Channels Iinput Level |
Individual 24-bit Sigma/Delta per each channel, with DSP each 6 channels, integrated digital antialiasing filter Up to 48 Ch. 5Vpp, 20Vpp, differential Input |
Calibration | Built-in |
Sampling | Selectable from 10Hz to 8kHz |
Bandwidth | DC – 4,000 Hz |
Dynamic Range | > 134 dB |
Programmable Gain Filter Anti Aliasing |
1-2-4-8-16-32-64-128 Digital Filter FIR. Frequency attenuation by Nyquist (1/2 sample rate) >–120dB, cut frequency 0,4 of sample rate |
EXTERNAL INTERFACES | |
GPS Antenna | GPS time synchronization, RS-422 interface |
Power | 10VDC to 18 VDC (adapter 120/240 V AC optional), automatic turn OFF when battery <10,2 V, turn ON >11,8V |
Seismic Sensors | Seismometers, Accelerometers Force Balance, ICP, piezoeletrics, MEMS, Geophones, |
Other Interfaces | Ethernet TCP/IP via cavo/radio wireless, modem, GPS |
PHYSICAL CHARACTERISTICS | |
Container Features | Metallic cabinet, protection IP656 |
Working Temperature | -20 °C - +70 °C |
Dimensions (LxWxH) | 650x400x250mm – 400x400x250 |
Weight | 15Kg |
Umidity | 0-100% non condensed |
9 300,00 €
69,00 €
60,00 €
75,00 €