AQM Remote Air Quality Monitor 0.1 CFM (2.83 LPM) with Standard Calibration: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm

New

  • Industry's highest concentration of 15,000,000 particles t³ @ 10% coincidence loss
  • Ideal for use in research, industrial health & safety, and indoor air uality applications
  • The most comprehensive internal self-diagnostics of any air quality monitor
  • Remote diagnostics allow for remote service investigation through the Internet
  • Can be used as bench-top or wall-mounted for fixed installation
  • Internet of Things (IoT) communication allows for network or cloud-based data options

Add to wishlist

Type of Instrument Particles in Air Monitor
The instrument measures: Optical Particle Counting
Instrument for: Particles in the Air
Function: Research-Industrial-Health

The Particles Plus 5301-AQM Air Quality Monitor measures particles from 0.3 μm to 25.0 μm and has a mass concentration mode that approximates density in μg/m³.
The unit displays simultaneous PM1, PM2.5, PM5, PM10 and TPM data, while monitoring CO2, Temperature, Humidity, Barometric Pressure and optional TVOC.
With an internal 0.1 CFM (2.83 LPM) vacuum pump, the 5301-AQM can be used as a stand-alone instrument or be easily integrated into a building management system via Ethernet or (optional) Wireless 802.11 b/g.
Particles Plus counters can be controlled and monitored remotely via web browser.
The 5301-AQM’s mass concentration mode allows for density correction and refractivity index input for up to 6 particle size channels.

Features & Benefits:

Measures mass concentration in μg/m³ and indication of PM (Particle Matter)
Measures up to 6 channels of simultaneous data
Measures CO2, Temperature and Relative Humidity with user alarm set-points
Measures TVOC in parts per billion (Model 5302-AQM)
User adjustable single and two point sensor calibration offset
User-selectable channel sizes
Long-life laser diode technology
Internal 0.1 CFM (2.83 LPM) vacuum pump
Large easy-to-use icon driven color touch screen display
Stores up to 45,000 sample records, 1,000 sample locations and 50 recipes
Easy configuration and transferable from instrument to instrument
Connect using Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232
Static or dynamic IP address (DHCP)
Displays and externally prints environmental reports
Internal audible alarm with user selectable thresholds for all environmental parameters
User-definable reports
Ideal for fixed system ventilation rate monitoring
Complies with ISO 21501-4 and JIS B9921 standards
Easy to clean and wipe down with minimal particle traps
Seamless integration into a facility monitoring system
Light weight stainless steel enclosure allows for easy wall-mounted installation
2 year warranty, extended warranties available
Size Range 0.3 to 25 μm
Size Channels Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Flow rates 0.1 CFM (2.83 LPM)
Concentration Limit 4,000,000 Particles/ft³ @ 5% coincidence loss
Counting Efficiency 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Light Source Long Life Laser Diode
Zero Count <1 count / 5 minutes (<2 particles / ft³) (per ISO 21501-4 & JIS)
Count Modes Automatic, manual, real-time meter, cumulative/differential, count or concentration
Count Alarms 1 to 9,999,999 counts
Calibration NIST traceable
Display 4.3″ (10.9 cm) WQVGA (480×272) color touch screen
Vacuum Requirements External vacuum >15” (38.1 cm) of Hg
Number of Channels 6
Custom Size Channels Calibration for custom size channels available
Airflow Internally monitored
Audible Alarm Adjustable built-in alarm
Communication Modes Ethernet and USB
Optional Communication Modes Wireless 802.11 b/g, RS485 or RS232
Environmental Sensor Optional temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% relative humidity
Alarm Alarms on counts for all particle sizes, sensor failure, environmental sensors and flow
Standards ISO 21501-4 and JIS B9921
Calibration Recommended minimum once per year
External Surface Stainless steel
Dimensions (L x W x H) 5.2” x 2.3” x 8.9” (13.3 cm x 5.8 cm x 22.6 cm) includes barb fittings
Weight 2.6 lb (1.18 kg)
Accessories Quick start guide, operating manual on USB flash drive, isokinetic probe, power supply & cable
Optional Accessories Printed manual, temperature relative humidity sensor, isokinetic probes, purge filter, data cable, mounting bracket and sample tubing
Buffer Memory 45,000 sample records (rotating buffer) including particle count data and environmental data
Sample Time 1 second to 99 hours
Power 110 to 240 VAC 50/60 Hz universal in-line power supply
Operating Conditions 41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing
Storage Conditions 32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing
Warranty 2 Years. Extended warranties available.

Accessory Kit (included with the instrument):
Isoprobe Threaded 0.1 CFM (2.83 LPM) Nickel Plated Aluminum Ref.: PS-12041
Purge Filter Assembly 0.1 CFM (2.83 LPM) Ref.: AS-99002A
Temperature / RH Probe AQM 32-140°F (0-60°C) ±1°F (0.5°C), 0-100% ±2% Ref.: EE-80122A
Power Supply 15V ~2amp 100-240VAC (Select adapter -US, -EU, -UK or -CN) Ref.: EE-80127-XX
USB Cable 6' (1.8m) Ref.: AS-99022
AQM Series Calibration Certificate Ref.: CC-25002
AQM Series User Manual and Instrument Management Software (USB Key) Ref.: MN-24018

Complete Accessories List: