HHF2005HW With data logger hot-wire Anemometer

HHF2005HW

Omega

New

  • Real time data logger register year, month, date, hour, minute, and second: up to 16,000 records
  • Technology of hot wire for measurements of high precision low speed air
  • Available software and RS232 serial interface
  • The meter battery powered includes proof case to be able to transport it easily
  • The slim telescopic probe is ideal for grilles and diffusers
  • Large LCD with multiple screens, the brightness can be adjusted
  • Adjustable sampling time functions, adjust zero and data retention
  • It accepts thermocouples of type J or K

Add to wishlist

With real time data logger HHF2005HW hot-wire anemometer has several functions and a computer interface RS-232 that make suitable for applications such as environmental tests, balance of ventiladoresmotoressopladores, air conveyors, cleanrooms and flow hoods. What distinguishes the HHF2005HW of other hot wire anemometers is that it includes a real time data recorder that can store up to 16,000 entries. The HHF2005HW measures speed and air temperature and has a probe Jack input that accepts a thermocouple type J or K that can be used as a high accuracy thermometer. To enter the area on the instrument and measure the speed, the HHF2005HW can even determine the volume of air flow. Integrated standard and hot-wire Thermistors provide fast and accurate readings even at low speeds. For convenience, the HHF2005HW is battery-powered and has functions of automatic off and low battery warning. It includes a durable case for easy transport.

Unidades de la pantalla: m/s, km/h, millas/h, nudos, pies/min, MCM, PCM, °C, °F
Temperatura de funcionamiento: 0 a 50 °C (32 a 122 °F)
Humedad máxima: Humedad relativa inferior al 80% (sin condensación)
Tiempo de muestreo: 2 seg. a 8 horas, 59 min, 59 segundos

Alimentación: 4 pilas 'AA' (incluidas)
Corriente: Aproximadamente 21,5 mA cc (70 mA cc con sonda de hilo caliente)
Peso: aprox. 515 g (1,13 libras)
Dimensiones:
Instrumento: 203 x 76 x 38 mm (8,0 x 3,0 x 1,5')
Sonda telescópica: 12 mm (0,5') de diámetro, 280 a 940 mm (11,0 a 37,0') de longitud length
Pantalla LCD: 558 x 34 mm (2,3 x 1,3')1.3')

MediciónRangoResoluciónPrecisión
m/s 0.2 a 20 m/s 0.1 m/s ± (10% + lsd) de toda la escala
km/hr 0.7 a 72 km/hr 0.1 km/hr
millas/hr 0.5 a 44.7 millas/hr 0.1 millas/hr
nudo 0.4 a 38.8 nudos 0.1 nudos
ft/min 40-3940 ft/min 1 ft/min
Temp. aire (°C) 0 a 50°C 0.1°C ± 0.8°C
Temp. aire (°F) 32 a 122°F 0.1°F ± 1.5°F
Termómetro (termopar tipo J) -100.0 a 1100°C 0.1°C ± (0.2% + 0.5°C)
-50.1 a -100°C ± (0.2% + 1°C)
-58.0 a 2012°F 0.1°F ± (0.2% + 1°F)
-58.1 a -148°F ± (0.2% + 1.8°F)
Termómetro (termopar tip K) -50.0 a 1300°C 0.1°C ± (0.2% + 0.5°C)
-50.1 a -100°C ± (0.2% + 1°C)
-58.0 a 2372°F 0.1°F ± (0.2% + 1°F)
-58.1 a -148°F ± (0.2% + 1.8°F)

 

MediciónRangoResoluciónÁrea
CMM 0 a 36,000 CMM 0.001-1 CMM 0.001 a 30.0 m2
CFM 0 a 1,271,200 CFM 0.01-100 CFM 0.01 a 322.91 ft2