◆ Force: 150 N◆ Nominal voltage: 24 VAC/DC◆ Control: 2-/3-point◆ Stroke: depending adjustable spindle
Rotary actuator with fail-safe position for adjusting dampers in HVAC installations Running time: 3...5 s / 90° Torque: 15 Nm Nominal voltage: 24 VAC/DC Control: continuous control (0)2...10 VDC Damper size: up to approx. 3 m² Shaft coupling: clamp square 8-15 mm / round 8-20 mm
◆ % r.H., g/m³, g/kg, DP °C◆ -30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C◆ output 0-10 V, 4-20 mA, changer◆ heating function for condensation protection◆ accuracy ±3% r.H.◆ hinge lock technology
► Room operator panel device► 8 x Button with temperature up/ down, fan up/ down, sunblinds up/ down, light, and menu► Front in black or white► Modbus, NFC► Temperature, rel. Humidity, ext. switch/NTC, infrared receiver
change-over contact precipitation yes/no infrared light barrier system
Rotary actuator for adjusting dampers in HVAC installations
- Rotary actuator without spring return actuator- 24 VAC/DC, 2/3 point- Torque 30 Nm- Running time 150 s/90°- Connection with 1m cable- Feedback signal: 2x Auxiliary switch- Shaft coupling: Round 9-26 mm, square 9-18 mm- Assembly with mounting strip + screws
Rotary actuator for adjusting dampers in HVAC installations With feedback potentiometer: 5 kΩ
- Rotary actuator without spring return actuator- 120...230 VAC/DC, 2/3 point- Torque 20 Nm- Running time 60 s/90°- Connection with 1m cable- Feedback signal: 2x Auxiliary switch, Potentiometer- Shaft coupling: O 9-26 mm, square 9-18 mm- Assembly with mounting strip + screws
Spring return actuator for adjusting dampers in HVAC installations - Spring return actuator- 24 VAC/DC, continuous (0)2…10 V- Torque 10 Nm- Running time: motor 150 s/90°/ spring 20 s/90°- Connection with 1m cable- Feedback signal: (0)2…10 V- Shaft coupling: O 9-26 mm, square 9-18 mm- Assembly with mounting strip + screws
Spring return actuator for adjusting dampers in HVAC installations- Running time motor: 150 s / 90°- Running time spring: 20 s / 90°- Torque motor: 10 Nm- Torque spring: 10 Nm- Nominal voltage: 24 VAC/DC- Control: continuous control (0)2...10 VDC- Auxiliary switch: 2x freely adjustable- Damper size: up to approx. 2 m²- Shaft coupling: clamp...
- Spring return actuator- 24 VAC/DC, continuous (0)2…10 V- Torque 20 Nm- Running time: motor 150 s/90°/ spring 20 s/90°- Connection with 1m cable- Feedback signal: (0)2…10 V- Shaft coupling: O 9-26 mm, square 9-18 mm- Assembly with mounting strip + screws Option: Auxiliary switch
-40...+400°C PT100, PT500, PT1000 magnetic adhesive force 90 N
- VdS, CE, DIBt approval- Built-in control unit (independent)- 2 alarm relays, 1 service alarm, 1 system error relay, 1 low flow relay, Modbus- Quick and easy installation.- Flow indicator with high sensitivity.- 4 installation positions 0, 90, 180 and 270 °- Test hole in the cover ◆ Needed Accessory Venturi Tube for smoke detection in ducts
Measured Parameters: - wind speed- precipitation yes/no- brightness (east/south/west)- temperature- humidity- twilight
2 Models powered at 24 V AC / DC:WRG2 / O-10 - Output 0 - 10 VdcWRG2 / O-50 - Output 4 - 20 mA