◆ %RH and Pt100 temperature combined probe, with SICRAM module.◆ Stainless steel stem, stainless steel 20μ sintered filter. ◆ Cable length 5 m.◆ Operating range: -40…+150 °C, 0…100%RH.
At AlphaOmega-Electronics you will find the best range of Delta Ohm Probesand at the most competitive prices
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable length 5 m M12 connector.
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable L = 5 m. Supplied with base with levelling device.
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction. Measuring range: 0.1 ... 200,000 lux. Cable length 5 m M12 connector.
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction, dome in K5. Measuring range: 0.1 ... 200,000 lux. Supplied with base with levelling device. The cable (CPM12 AA5 ... D) has to be ordered separately.
Radiometric probe for measuring the irradiance in the UVA spectral range (315-400 nm, with peak at 360 nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 10 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVB spectral range (280-315nm, with peak at 305nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVC spectral range (220-280nm, with peak at 260nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Combined probe for measuring the illuminance (lux), with standard photopic spectral response, and for measuring the irradiance (W / m2) in the UVA spectral range (315-400 nm, with peak at 360 nm). Both sensors are equipped with diffuser for the correction according to the law.Illuminance measuring range: 0.3 ... 20⋅103 lux. Irradiance measuring range:...
First Class pyranometer according to ISO 9060. Output in μV / (Wm-2). Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, leveling device, connector and calibration report. On request 5 or 10 m cables with 4-pole M12 connectors.