HANDHELD METERS FOR TEMPERATURE, HUMIDITY, PRESSURE, AIR SPEED, LIGHT, ACOUSTICS, VIBRATIONS, AIR QUALITY, ENVIRONMENTAL AND WATER ANALYSIS, DATA LOGGERS...
22,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor, extended temperature range). Integrated pressure sensor.
22,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor.
24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor, extended temperature range).
24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).
24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with NTC10KΩ temperature sensor).
24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with temperature sensor integrated in the R.H. module).
22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC ... temperature and relative humidity combined probe with NTC10KΩ temperature sensor, and one for the temperature only probes with NTC10KΩ sensor (two combined T / RH probes can not be connected).
22,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), one for the pyranometer and one for the TP35878ISS ... Pt100 temperature probe for solar panel.
30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter.
26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PAR probe for the measurement of the photons flow in the chlorofyll range.
26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT03BL illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the leaf wetness sensor HP3501 ....
22,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the rain gauge and the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor).
24,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the pyranometer LP PYRA 03.
68,000 samples. Optional custom LCD display (option L). One input with M12 connector for Pt100 / Pt1000 temperature probes.
Temperature wireless data logger. 42,000 samples Optional custom LCD display (option L). Three inputs with M12 connector for Pt100 / Pt1000 temperature probes.
36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the TP35878ISS ... Pt100 temperature probe for solar panel, and one for the pyranometer.
28,000 samples. Optional custom LCD display (option L).Two inputs: one with M12 connector for the rain gauge and one with cable gland for the level sensor.
36,000 to 68,000 samples depending on the number of inputs used. Optional custom LCD display (option L). Four inputs with connector for K-J-T-N-E hermocouple temperature probes.
68,000 samples. Optional custom LCD display (option L). Fixed vertical probe with NTC10KΩ temperature sensor.
68,000 samples. Optional custom LCD display (option L). Fixed vertical probe with NTC10KΩ temperature sensor.
68,000 samples. Optional custom LCD display (option L). One input with M12 connector for NTC10KΩ temperature probes.
42,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector for NTC10KΩ temperature probes.