HANDHELD METERS FOR TEMPERATURE, HUMIDITY, PRESSURE, AIR SPEED, LIGHT, ACOUSTICS, VIBRATIONS, AIR QUALITY, ENVIRONMENTAL AND WATER ANALYSIS, DATA LOGGERS...
24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor).
24,000 samples. Optional custom LCD display (option L). One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).
24,000 samples. Optional custom LCD display (option L). Fixed vertical probe (with NTC10KΩ temperature sensor).
24,000 samples. Optional custom or graphic LCD display (option L or G). Fixed vertical probe (with temperature sensor integrated in the R.H. module).
For clean rooms. 22,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Pressure input for tubes with 5 mm internal diameter. Metal pressure inputs with tube clamp ring to minimize pressure losses.
22,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Pressure input for Ø 5 mm tubes.
44,000 samples. Optional graphic LCD display (option G). The sensors are all inside the housing. Temperature sensor integrated in the R.H. module
44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Photodiode with spectral response similar to the standard photopic curve V (λ).
32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 P-A illuminance and UVA irradiance combined probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Photodiode with spectral response similar to the standard photopic curve V (λ).
44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 UVB irradiance probe.
44,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 UVC irradiance probe.
68,000 samples. For clean rooms. Optional custom LCD display (option L). Pressure input for tubes with 5 mm internal diameter. Metal pressure inputs with tube clamp ring to minimize pressure losses.
68,000 samples. Optional custom LCD display (option L). Pressure input for Ø 5 mm tubes.
-200ºC to + 650ºC depends on probe used Temperature wireless data logger. Optional graphic LCD display (option G). M12 connector for Pt100/Pt1000 temperature probes.Instrument operating temperature / humidity: -20…+70 °C / 0…85 %RH.Supplied with 3.6V non-rechargeable Li-SOCl2 battery and HD35.03 wall mount support.The temperature probes (TP35.1…) have to...
Temp. Range -200ºC to +650ºC depending on the sensor used
68,000 samples. Optional custom LCD display (option L). Fixed vertical probe with NTC10KΩ temperature sensor.
68,000 samples. Optional customized LCD display (opción L). One input with M12 connector for NTC10KΩ temperature probes.
Wireless module with two relay outputs for signalling alarm events. Controlled by the base unit, it allows to activate more signalling devices (sirens, blinking lights, etc.) or actuators.
Number of samples that can be stored: from 36,000 to 68,000 depending on the number and type of connected sensors. Optional graphic LCD display (option G).
Front dimensions 120x122 mm. It can measure temperature, humidity, atmospheric pressure, solar radiation, rainfall quantity, wind speed and direction. It stores the measures in its internal memory (from 28,000 to 58,000 samples depending on the number of detected quantities) and transmits the logged data to the base unit at regular intervals or upon...
68,000 samples. Optional custom LCD display (option L). Fixed vertical probe.
68,000 samples. Optional custom LCD display (option L). Fixed vertical probe.