Catalog
Loading...
fuentes RSS
No RSS feed added
Waterproof Housing. Powered by the internal battery. Supplied with: internal lithium-thionyl chloride (Li-SOCl2) not rechargeable battery BAT-2013DB, operating manual. Fixed external antenna. It can be wall mounted by means of the optional HD35.24W flange or fixed on a Ø 40 mm mast by means of the HD2003.77/40 clamping (optional). Optional HD9217TF1...
Wireless module with two relay outputs for signalling alarm events. Controlled by the base unit, it allows to activate more signalling devices (sirens, blinking lights, etc.) or actuators.
Data logger with integrated Web Server (except HD50R-MB). Depending on the model, it measures temperature, humidity, atmospheric pressure, carbon dioxide and illuminance.
Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for NTC10KΩ temperature probes.
Number of samples: Min = 744,740, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Two inputs with M12 connector for NTC10KΩ temperature probes.
Number of samples: Min = 615.220, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Three inputs with M12 connector for NTC10KΩ temperature probes.
Number of samples: 906,640. Optional custom (option L) or graphical (option G) LCD display. Fixed vertical probe with NTC10KΩ temperature sensor.
Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).
Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517ETC ... temperature and relative humidity combined probe (with Pt100 temperature sensor).
Number of samples: Min = 388.560, Max = 906.640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical probe (with NTC10K temperature sensor).
Number of samples: Min = 356,180, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. One input with M12 connector for the HP3517TC ... temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Integrated pressure sensor.
Número de muestras: Mín. = 356,180, Máx. = 906,640 (segundo o número de cantos almacenados). Opcional pantalla LCD personalizada (opção L) ou gráfica (opção G). Una entrada con M12 para a sonda combinada HP3517ETC ... de temperatura e umidade relativa (com sensor de temperatura Pt100). Sensor de presión integrado.
Number of samples: Min = 356,180, Max = 906,640 (depending on the number of stored quantities).Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter.
Number of samples: Min = 323,800, Max = 906,640 (depending on the number ofstored quantities). Optional custom (option L) or graphical (option G) LCD display.Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. Integrated pressure sensor.
◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral...
◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with...
Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT...
◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35...
◆ Data logger with four terminal header inputs for the connection of:- transmitters with 4 ÷ 20 mA, 0 ÷ 1/0 ÷ 10 V or 0 ÷ 50 mV output- Pt100 / Pt1000 sensors, K, J, T, N, E thermocouples- potentiometric sensors◆ Number of samples: Min = 615.220, Max = 1,165,680 (depending on the number of stored quantities) depending on the number and type of connected...
Data logger with Master RS485 Modbus-RTU interface for acquiring sensors with RS485 Modbus-RTU output (for example an anemometer of the HD52.3D ... series). A proprietary protocol is also available for connecting anemometers of the HD2003 series. A voltage-free contact input allows connecting to tipping bucket rain gauge.It communicates with the PC / PLC...
◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected) and transmits the acquired data by email, via FTP and to an HTTP (Cloud) server. USB output. Optional custom LCD display...
◆ HD33M.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa.◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected)...
100 ... 240 Vac / 24 Vdc power supply unit with switch. Wall-mount or attachment on to ∅ 40 mm mast (to be specified when ordering). Includes the fixing accessories.
Unidad de suministro de energía del panel solar con interfaz SDI-12 para leer el voltaje de la fuente de alimentación. Incluye una batería de 12 Vdc / 7.2 Ah y un regulador de carga. La salida de la fuente de alimentación es el voltaje no regulado de la batería interna. Carcasa estanca IP 67 Al realizar el pedido, especifique si el cable de alimentación...