32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 P-A illuminance and UVA irradiance combined probe. Photodiode with spectral response similar to the standard photopic curve V (λ). Integrated pressure sensor.
32,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Photodiode with spectral response similar to the standard photopic curve V (λ). Integrated pressure sensor.
42,000 samples. Optional custom LCD display (option L). One input with M12 connector for the pyranometer.
24,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), and one for the pyranometer LP PYRA 03.
36,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector: one for the TP35878ISS ... Pt100 temperature probe for solar panel, and one for the pyranometer.
22,000 samples. Optional custom LCD display (option L). Three inputs with M12 connector: one for the HP3517TC2 temperature and relative humidity combined probe (in AISI 304, with NTC10KΩ temperature sensor), one for the pyranometer and one for the TP35878ISS ... Pt100 temperature probe for solar panel.
28,000 samples. Optional custom LCD display (option L). Two inputs with M12 connector for the pyranometer and the rain gauge.
Applications: PV system performance monitoring General solar resource monitoring Indoor simulated solar testing Meteorological networks
The new SR15 digital pyranometer series is ideal for general first class high-accuracy measurements in PV system performance monitoring and meteorology. Applications: PV system performance monitoring General solar resource monitoring Indoor simulated solar testing Meteorological networks
30,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). One input with M12 connector for the LP 35 PHOT03BL illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
26,000 samples. Optional custom LCD display (option L). Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 sensor with removable protection filter. One input with M12 connector for the LP 35 PHOT illuminance probe. Photodiode with spectral response similar to the standard photopic curve V (λ).
◆ Number of samples: Min. = 356,180, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed combined vertical temperature and relative humidity probe (with NTC10KΩ temperature sensor).◆ One input with M12 connector for the LP 35 PHOT lighting probe.◆ Photodiode with spectral...
◆ Number of samples: Min. = 323,800, Max. = 906,640 (according to the number of quantities stored).◆ Optional customized (option L) or graphic (option G) LCD display.◆ Combined vertical temperature and fixed relative humidity probe (with NTC10KΩ temperature sensor). ◆ One input with M12 connector for the LP 35 PHOT illumination probe.◆ Photodiode with...
Number of samples: Min = 323,800, Max = 906,640 (depending on the number of stored quantities). Optional custom (option L) or graphical (option G) LCD display. Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor). Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35 PHOT...
◆ Number of samples: Min = 291,420, Max = 906,640 (depending on the number of quantities stored).◆ Optional customized LCD screen (option L) or graphic (option G).◆ Fixed vertical temperature and relative humidity combined probe (with NTC10KΩ temperature sensor).◆ Fixed CO2 probe with removable protection filter. One input with M12 connector for the LP 35...
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction. Measuring range: 0.1 ... 200,000 lux. Cable length 5 m M12 connector.
Adjustable wall support for Ø 30 mm photometric and radiometric probes.
Radiometric probe for measuring the irradiance in the UVA spectral range (315-400 nm, with peak at 360 nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 10 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVB spectral range (280-315nm, with peak at 305nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVC spectral range (220-280nm, with peak at 260nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable length 5 m M12 connector.
Combined probe for measuring the illuminance (lux), with standard photopic spectral response, and for measuring the irradiance (W / m2) in the UVA spectral range (315-400 nm, with peak at 360 nm). Both sensors are equipped with diffuser for the correction according to the law.Illuminance measuring range: 0.3 ... 20⋅103 lux. Irradiance measuring range:...
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable L = 5 m. Supplied with base with levelling device.
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction, dome in K5. Measuring range: 0.1 ... 200,000 lux. Supplied with base with levelling device. The cable (CPM12 AA5 ... D) has to be ordered separately.