Data Loggers, Temperature and Humidity Probes, Lighting Probes, Net Radiation Sensors, Luxmeters, Rain Gauges, CO and CO2 Recorders, Immersion, Penetration and Contact Probes, Ultrasonic Anemometers, Multisensor for Optical Radiation, Microclimate Analyzers, Pyrgeometers , Sound le...
Data Loggers, Temperature and Humidity Probes, Lighting Probes, Net Radiation Sensors, Luxmeters, Rain Gauges, CO and CO2 Recorders, Immersion, Penetration and Contact Probes, Ultrasonic Anemometers, Multisensor for Optical Radiation, Microclimate Analyzers, Pyrgeometers , Sound level meters, Leaf Wetness Sensors...
◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected) and transmits the acquired data by email, via FTP and to an HTTP (Cloud) server. USB output. Optional custom LCD display...
◆ HD33M.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa.◆ You can measure temperature, humidity, solar radiation, amount of rain, wind speed, and direction. It stores the measurements in its internal memory (from 128,000 to 440,000 samples depending on the number of quantities detected)...
100 ... 240 Vac / 24 Vdc power supply unit with switch. Wall-mount or attachment on to ∅ 40 mm mast (to be specified when ordering). Includes the fixing accessories.
Unidad de suministro de energía del panel solar con interfaz SDI-12 para leer el voltaje de la fuente de alimentación. Incluye una batería de 12 Vdc / 7.2 Ah y un regulador de carga. La salida de la fuente de alimentación es el voltaje no regulado de la batería interna. Carcasa estanca IP 67 Al realizar el pedido, especifique si el cable de alimentación...
Wireless data logger in IP 67 waterproof housing, specifically designed for monitoring perishable goods during transport. Front dimensions 120x122 mm. It can measure temperature, humidity and detect the state of an external voltage-free contact. It stores the measures in its internal memory (from 136,000 to 440,000 samples depending on the number of...
HD33T.GSM data logger equipped with an internal barometric sensor. Atmospheric pressure measuring range: 300 ... 1100 hPa.
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction. Measuring range: 0.1 ... 200,000 lux. Cable length 5 m M12 connector.
Adjustable wall support for Ø 30 mm photometric and radiometric probes.
Radiometric probe for measuring the irradiance in the UVA spectral range (315-400 nm, with peak at 360 nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 10 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVB spectral range (280-315nm, with peak at 305nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring the irradiance in the UVC spectral range (220-280nm, with peak at 260nm), diffuser for cosine correction. Measuring range: 1⋅10-3 ... 100 W / m2. Cable length 5 m M12 connector.
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable length 5 m M12 connector.
Combined probe for measuring the illuminance (lux), with standard photopic spectral response, and for measuring the irradiance (W / m2) in the UVA spectral range (315-400 nm, with peak at 360 nm). Both sensors are equipped with diffuser for the correction according to the law.Illuminance measuring range: 0.3 ... 20⋅103 lux. Irradiance measuring range:...
Radiometric probe for measuring PHOTONS FLOW (light flow in the field of photosynthesis of chlorophyll). Cosine correction. Measuring range 0 ... 5000 μmol m-2s-1. Cable L = 5 m. Supplied with base with levelling device.
Photometric probe for measuring illuminance, CIE photopic filter, spectral response according to the standard photopic curve, diffuser for cosine correction, dome in K5. Measuring range: 0.1 ... 200,000 lux. Supplied with base with levelling device. The cable (CPM12 AA5 ... D) has to be ordered separately.
First Class pyranometer according to ISO 9060. Output in μV / (Wm-2). Supplied with: shade disk, cartridge with silica-gel crystals, 2 spare sachets, leveling device, connector and calibration report. On request 5 or 10 m cables with 4-pole M12 connectors.
The DO9403T-R1 pH transmitter converts the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal. The pH or Redox electrode input circuit is galvanically isolated from the 4÷20 mA output signal. An LCD indicator allows to display the value of the process signal and the various parameters. The accurate design and choice of the...
DO9785T/DO9765T pH transmitters convert the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal. The pH electrode input circuit is galvanically insulated against the 4÷20 mA output signal.An LCD indicator allows viewing of the process signal value and of the various parameters. The accurate design and choice of components make...
This new line of anemometers is the result of our own R&D and comes, like all Delta OHM products, from our own production site in Italy. The top model of the HD51 series can even withstand an extreme wind speed of 100 meters/ second without giving up!
Portable luxmeter for measuring illuminance, luminance, PAR, irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve). Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. LP471 series probes with...
Portable measuring data logger for measuring and logging CO, CO2, Atmospheric Pressure, Temperature and Humidity.