Hand Infeed Temperature Probe with PTFE-Hand Grip and Silicone-Cable (-50 +600°C)
5 m glass fibre/stainless steel netting (2x0,22 mm²) -30...+350°C Pt100, Pt500, Pt1000
5 m glass fibre/stainless steel netting (2x0,22 mm²) -30...+350°C Pt100, Pt500, Pt1000
Stainless steel with glass fiber mesh surface temperature sensor (- 30 +500°C) 5 metre cable -30...+500°C PT100, Pt500, PT1000 stainless steel contacting block
Stainless steel with glass fiber mesh surface temperature sensor (- 30 +400°C) 5 metre cable -30...+400°C PT100, Pt500, PT1000 stainless steel contacting block
Radiation Temperature Sensor - Outdoor (-30 +75°C) -30...+75°C PT100, PT1000, Ni, NTC, KTY aluminium globe measuring of the thermal radiation
RSF/E Radiation Temperature Sensor - Room (-30 +75°C) -30...+75°C PT100, PT1000, Ni, NTC, KTY aluminium globe
Radiation Pendulum Temperature Sensor (-30 +75ºC) -30...+75°C Choose from: Pt100, Pt500, Pt1000, Ni1000, KTY, NTC, LM235Z (other on request)
-30...+60°C PT100, PT1000, Ni, NTC, KTY modern housing design mounting in a suspended ceiling or plasterboard wall
-10...+10°C protection type IP65 capillary length 3-6 m
Capillary Thermostat with Change-Over Contact (-35 +280°C)
Humidity Transducer with Pendular Probe (0...100% r.H)
Humidity Transducer with Pendular Probe (0...100% r.H) without display
0...100% r.H. accuracy ±3% r.H. output 0-10 V, 4-20 mA heating function for condensation protection
0...100% r.H. accuracy ±3% r.H. output 0-10 V, 4-20 mA heating function for condensation protection
% r.H., g/m³, g/kg, DP °C -30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C output 0-10 V, 4-20 mA
% r.H., g/m³, g/kg, DP °C -30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C output 0-10 V, 4-20 mA
► % r.H., g/m³, g/kg, DP °C► -30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C scales► outputs: 0-10 V, 4-20 mA, changer► heating function for condensation protection► hinge lock technology► Outputs to choose from: - Rel. Humidity: 2 x 4-20mA or 2 x 0-10V - Temperature: 2 x 4-20mA or 2 x 0-10V
Pressure Switch for Non-aggressive Gases, mechanical (Minimum order 2 und)
CO2: 0-2000 ppm Accuracy: ± 50 ppm, ± 1 K Output: 0-10 V Output relay for alarms
Room Air Quality Sensor for Mixed Gas (VOC) with LED Display 0...100% mixed gas VOC 0-10 V, 0/4-20 mA, Relay automatic re-calibration LED status lamp
Certified by VdS in Germany, G207134 Servicealarm Quick and simple installation with bayonet