Transducers and transmitters are virtually the same thing, the main difference being the kind of electrical signal each sends. A transducer sends a signal in volts (V) or millivolt (mV) and a transmitter sends a signal in milliamps (mA).
Both transducers and transmitters convert energy from one form to another and gi...
Transducers and transmitters are virtually the same thing, the main difference being the kind of electrical signal each sends. A transducer sends a signal in volts (V) or millivolt (mV) and a transmitter sends a signal in milliamps (mA).
Both transducers and transmitters convert energy from one form to another and give an output signal. The signal is directed to any device that interprets it and uses it to display record or alter the pressure in a system.
So how do you decide whether it is best to use a transducer or transmitter for you application? Transducers and transmitters are virtually the same thing, the main difference being the kind of electrical signal each sends. A transducer sends a signal in volts (V) or millivolt (mV) and a transmitter sends a signal in milliamps (mA). If the electrical connections in your process are short, such as in laboratory or inside an electronics enclosure, a pressure transducer is more desirable as they tend to be smaller and there are very few active electronic components that can be upset by electromagnetic interference.
For demanding humidity measurements.Measure moisture in harsh environments with the instrument you can trust. Vaisala HUMICAP® Humidity and Temperature Transmitter, HMT330 Series is designed for demanding industrial applications where stable measurements and extensive customization are essential.Looking for HMT330 performance with interchangeable probes...
MMT330 Series for Hydraulic Systems and Transformer Oil Lubrication and Monitoring.
► ConvenientReference oil is not required for recalibration.► Easy online process checkNo need to drain the oil. The probe can be inserted directly into the process pipeline through a ball valve, without draining oil into the system.► Economical operation with multiple probesCompatible with carbon dioxide, humidity and dew point probes, making it a...
The DO9403T-R1 pH transmitter converts the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal. The pH or Redox electrode input circuit is galvanically isolated from the 4÷20 mA output signal. An LCD indicator allows to display the value of the process signal and the various parameters. The accurate design and choice of the...
DO9785T/DO9765T pH transmitters convert the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal. The pH electrode input circuit is galvanically insulated against the 4÷20 mA output signal.An LCD indicator allows viewing of the process signal value and of the various parameters. The accurate design and choice of components make...
Dual Relays for Relative Humidity and Delta Ohm Temperature
- Meausurement of the exact content of PM1.0, PM2.5 and PM10.- Stand-alone unit, easy to integrate in Automatic Weather Stations.- Easy Cloud Connection.
Temperature and humidity outdoor, indoor probe with 4-20mA output Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
Green LED glows: CO2 concentration 0 to 1000 ppmYellow LED glows: CO2 concentration from 1001 to 1200 ppmRed LED glows - CO2 concentration 1201 ppm and more
Panel mounting conductivity transmitter in a 96x96 housing with dual LCD (measurement + temperature), output 4...20mA. The cell constant, the range and the temperature coefficient are completely configurable. 2-wire passive transmitter or 4-wire active transmitter. Power supply in active mode 24 Vac, on request 230 Vac, in passive mode 10...35 Vdc.
- 0-20 m/s, 0...+50°C, 0-200.000 m³/h - 0-10 V, 4-20 mA - LCD display, relay - 5 scales per device
Atmospheric pressure transmitter. Outdoor, indoor use. Barometric pressure transmitter for outdoor and indoor use.Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.
Barometric transmitter to wall mount for indoor use, with 0 ... 1 Vdc analog output. Measuring range 600 ... 1100mbar. Power supply 10 ... 40 Vdc. Working temperature -30 ° C ... 60 ° C.Suitable for installation in the housings for weather stations HD32.35, HD32.35FP, HD32.36 and HD32.36FP.
The ultrasonic liquid level transmitter AO-L-03 is a type of non-contact, high reliability, high cost of performance, easy installation and maintenance of the material level measuring instrument.
0 μg/m³ ... 1000 μg/m³ 0-10 V, 4-20 mA, Changer LCD-Display
- Choose Range from: 0… 25% vol. or 0… 100% vol. - Active output, 0-10V - LCD Display
SP1A air pressure transmitter is ready for installations in wide temperature range and offers measurement range of 600…1100 hPa. It may be used for multiple applications for indoor as well as outdoor applications. Thanks to the SDI-12 compatibility, it is suitable for GSM/GPRS Data Logger RADIO or can be integrated with other manufacturers’ equipment.
Relative or differential low pressure transmitter and data logger designed for wall flush-mounting The HD50CR is the ideal solution for monitoring of differential pressure, temperature and humidity in Clean Room applications.
ATEX certified relative humidity temperature transmitter. Outdoor, indoor use. ATEX certification for use in potentially explosive environments.
◆ % r.H., g/m³, g/kg, DP °C◆ -30...+70°C, -20...+80°C, 0...+50°C, 0...+100°C◆ output 0-10 V, 4-20 mA, changer◆ heating function for condensation protection◆ accuracy ±3% r.H.◆ hinge lock technology